background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                          
 
 
 
 
 
 
 
 
 
 
 
 
 
 
       

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. 

PLEASE SAVE THESE INSTRUCTIONS 

 
 
 

 

Lo-Carbon

 

PureAir Home  

Positive Input Ventilation 

Unit 

Stock Ref. N° 
 

479090 – PureAir Home 

479091 – PureAir Home with Heater 

479092 – PureAir Home FD 

 

Installation and Wiring Instructions 

 

220-240V~50Hz 

 

Summary of Contents for Lo-Carbon PureAir Home FD

Page 1: ...H THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon PureAir Home Positive Input Ventilation Unit Stock Ref N 479090 PureAir Home 479091 PureAir Home with Heater 479092 PureAir Home FD Install...

Page 2: ...2...

Page 3: ...ion concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without sup...

Page 4: ...t blocked These may not be present in older properties however there should be enough leakage to accommodate the requirements of the Lo Carbon PureAir Home unit One method of checking this is by enter...

Page 5: ...entering the dwelling has passed through the filter first Ensure that the screw eye is attached to the beam strongly enough and that the beam is in sufficient condition to withstand the load The unit...

Page 6: ...the ceiling Fig 5 It is important not to over tighten these screws as this may warp the diffuser Fit the free end of the flexible ducting to the diffuser spigot using the worm drive clip supplied The...

Page 7: ...er spigot see Fig 7 where fitted to the unit there are locating pins that fix the heater to the unit using a bayonet fitting and the locking screw When fitted at the diffuser end make sure the directi...

Page 8: ...should be capable of disconnecting all poles having a contact separation of at least 3mm PureAir Home PureAir Home with Heater unit Ensure the local AC power supply is isolated The product has a pre w...

Page 9: ...ings will then be applied There are three buttons on the front of the unit The button is used to increase the value of a setting the button is used to reduce the value of a setting and the Mode button...

Page 10: ...ation is required optional F7 filters can be used These filters are effective at removing finer particles such as particulate emissions from diesel engines In urban areas close to main roads F7 filter...

Page 11: ...ired it is recommended not to use this setting By reducing the trickle speed threshold the fan will run at higher speed more often this would be helpful in a property with persistent damp problems Inc...

Page 12: ...y be necessary to use the manual speed selection to meet the required flow rate It is the responsibility of the installer to ensure that appropriate speeds are selected M SERVICING AND MAINTENANCE WAR...

Page 13: ...Power Input W Max Flow Rate 14 00 14 00 14 00 LWA Sound Power Level dB 35 53 35 53 35 53 Ref Flow Rate m3 s 0 04 0 04 0 04 Ref Pressure Diff Pa N A N A N A SPI W m3 h 0 09 0 09 0 09 Control Factor Co...

Page 14: ...14...

Page 15: ...15...

Page 16: ...contractor against faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the...

Reviews: