Installation and Wiring Instructions 

 

 

 

 

 

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE 
INSTRUCTIONS.  

 

Lo-Carbon 
Quadra SELV

 

 
 

IPX7 

Safety Extra Low Voltage 

 

Stock Ref. N° 

 
Quadra SVTP 

442865 

Quadra SVHTP  

442866 

Quadra SVTM  

442867 

 

Summary of Contents for Lo-Carbon Quadra SELV Series

Page 1: ...Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon Quadra SELV IPX7 Safety Extra Low Voltage Stock Ref N Quadra SVTP 442865 Quadra SVHTP 4...

Page 2: ...hin reach of a person using a fixed bath or shower i e in a nearby wall However the fan must not be placed where it could be submerged in water or regularly exposed to direct water spray e g from a sh...

Page 3: ...installed and that the optional Filter fig 3 could be removed for cleaning The cardboard fitment in the packaging can be used as a template 3 Set up the appropriate speed selection and other features...

Page 4: ...and the flange for the thickness of the panel so that the clips can spring open behind the panel 5 Set up the appropriate speed selection and other features as outlined in Section B SETUP 6 Remove th...

Page 5: ...r RH ii To RAISE the Set Point turn the Humidity Adjuster figs 4 7 CLOCKWISE This makes the fan less sensitive to RH i e the fan will come on at a higher RH C WIRING WARNING THE FAN AND ANCILLARY CONT...

Page 6: ...embly and Impeller in warm soapy water if they are dirty Do not use abrasive cleaners Dry the parts before replacing them 7 Turn the power to the Fan back on The fan has sealed for life bearings which...

Page 7: ...Terminal Block Cover Spigot Cover Assembly Chassis Assembly Impeller Optional Filter Fig 4 Internal Terminal Block Cover Cable Clamp Terminal Block Timer and Humidity Adjustment Speed and Installation...

Page 8: ...Fig 5 Frame from optional Flush Mount Kit Back Box Fig 6 Panel Clip Screw 4 off Panel Clip 4 off...

Page 9: ...e set point Speed Selection Switches Example shown is boost speed of 15 l s and normal trickle speed of 6 l s Installation Type Selection Switches Through the wall installation 1 5m 100mm ducting with...

Page 10: ...Fig 9 Wiring diagram without LS connection Fig 10 Wiring diagram with LS connection N Ls 0V Fan Controller LS L N SELV Supply 24V DC 3A UK 24V LS 24V 0V N Ls 0V Fan Controller LS L N SELV Supply 24V...

Page 11: ...l Factor CTRL 0 65 0 65 0 65 Control Typology Clock Control Local Demand ControlLocal Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchanger...

Page 12: ...e repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to a...