background image

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig.7

 Removing the grille for wiring and setting the controls 

 
 

   

                          

 

 
Pull front panel as shown. 

Loosen screws – DO NOT REMOVE FROM GRILLE 

 

(the screws are self-retaining) 

 
 

    

                

 

 
Pull inner grille away from housing as shown.  

 

 
 

   

         

Open up the internal cover 
to access the spirit level 
bubble and terminals. 

DOWN 

Mode/Set

UP

Summary of Contents for Lo-Carbon Responce Series

Page 1: ...tructions Stock Ref N 494143 Response 7 494144 Response 7 Pro 494150 Response 7 SELV 494149 Response 7 Pro SELV PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTION...

Page 2: ......

Page 3: ...installation within Zones 1 2 C The Fan should be provided with a local isolator switch capable of disconnecting all poles having a contact separation of at least 3mm D Ensure that the mains supply V...

Page 4: ...the fan to suit its installation The display is also used to show the day logger and power run meter The fan can be wall window or panel ceiling mounted ACCESSORIES not supplied WALL FITTING KIT A ran...

Page 5: ...lace the front panel EXTERIOR WALL MOUNTING 1 For wall mounting cut a 117mm diameter hole through the wall and insert the wall sleeve Slope the sleeve slightly downwards away from the fan Where necess...

Page 6: ...enclosed or covered with insulation The fan is a class ll double insulated product and MUST NOT be earthed 1 Select and follow the appropriate wiring diagram Fig 1 2 3 or 4 5 6 2 Check all connection...

Page 7: ...ll run for 15 minutes first showing the day logger then cycling between displaying Airflow rate Pro models only other models display speed setting Estimated duct pressure Pro models only Current RH HT...

Page 8: ...c n normal LS overrun c Y comfort mode c n unl Enable disable lock code loc lock code enabled unl lock code disabled unlocked unl Menu lock code Up down selects current digit X moves to next digit 10c...

Page 9: ...d rise function to detect rapid rises in humidity when the ambient rH is under the threshold setting If a rapid rise is detected the fan will increase in speed proportionally between the trickle and b...

Page 10: ...errun duration of 5 minutes will take place This will override LS comfort mode boosting the fan immediately An activation when a Pullcord LS Light Switch boost is already active shall cancel overrun t...

Page 11: ...press of the Mode button will return the fan to the commissioning menu D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTE...

Page 12: ...us boost 1 with no trickle facility The fan is internally fused Fig 3 Continuous trickle with boost facility The fan is internally fused Fig 1 Continuous trickle with boost via pull cord The fan is in...

Page 13: ...facility SELV models Fig 6 Continuous trickle with boost facility via LS or internal pullcord SELV models Fig 4 Continuous trickle with pullcord boost SELV models N L 1 Phase Supply 220 240V 50Hz FUSE...

Page 14: ...g the controls Pull front panel as shown Loosen screws DO NOT REMOVE FROM GRILLE the screws are self retaining Pull inner grille away from housing as shown Open up the internal cover to access the spi...

Page 15: ......

Page 16: ...oduct rating label attached to the unit Has not been subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUAR...

Reviews: