background image

Open up the internal cover to access 

The spirit level bubble 

PANEL/CEILING/ INTERIOR WALL MOUNTING 
 

1. 

Cut a 105mm diameter hole. 

2. 

Remove the front panel by carefully 
pulling it away from the fan. Loosen 
the two self-retaining screws and 
remove the inner grille by carefully 
pulling it away from the housing.   

3. 

Using the built in spirit level bubble 
as an aid.

 

Mark the screw centres 

through the holes in the fan back 
plate. Drill, plug and screw into 
position. Attach ducting as required 
for the installation.  

4. 

Wire the fan as described in 
Section B-Wiring. Adjust any settings 
as required (see Section C-Setup). 

5. 

After installation, ensure impeller rotates freely. 

6. 

Replace the inner grille and tighten the retaining screws.  

7.   Replace the front panel.  
 
 

EXTERIOR WALL MOUNTING  

1. 

For wall mounting cut a 117mm diameter hole through the wall and 
insert the wall sleeve. Slope the sleeve slightly downwards away 
from the fan. Where necessary cut to length and cement both ends 
into position flush with the wall faces.  

2. 

Fix exterior grille into position with the louvres positioned 
downwards.  

3. 

Remove the front panel by carefully pulling it away from the fan. 
Loosen the two self-retaining screws and remove the inner grille by 
carefully pulling it away from the housing.   

4. 

Using the built in spirit level bubble as an aid.

 

Mark the screw 

centres through the holes in the fan back plate. Drill, plug and 
screw into position.  

5. 

Wire the fan as described in Section B-Wiring. Adjust any settings 
as required (see Section C-Setup). 

6. 

After installation, ensure impeller rotates freely. 

7. 

Replace the inner grille and tighten the retaining screws.  

8.   Replace the front Panel. 
 
 
 

Summary of Contents for Lo-Carbon Responce Series

Page 1: ...tructions Stock Ref N 494143 Response 7 494144 Response 7 Pro 494150 Response 7 SELV 494149 Response 7 Pro SELV PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTION...

Page 2: ......

Page 3: ...installation within Zones 1 2 C The Fan should be provided with a local isolator switch capable of disconnecting all poles having a contact separation of at least 3mm D Ensure that the mains supply V...

Page 4: ...the fan to suit its installation The display is also used to show the day logger and power run meter The fan can be wall window or panel ceiling mounted ACCESSORIES not supplied WALL FITTING KIT A ran...

Page 5: ...lace the front panel EXTERIOR WALL MOUNTING 1 For wall mounting cut a 117mm diameter hole through the wall and insert the wall sleeve Slope the sleeve slightly downwards away from the fan Where necess...

Page 6: ...enclosed or covered with insulation The fan is a class ll double insulated product and MUST NOT be earthed 1 Select and follow the appropriate wiring diagram Fig 1 2 3 or 4 5 6 2 Check all connection...

Page 7: ...ll run for 15 minutes first showing the day logger then cycling between displaying Airflow rate Pro models only other models display speed setting Estimated duct pressure Pro models only Current RH HT...

Page 8: ...c n normal LS overrun c Y comfort mode c n unl Enable disable lock code loc lock code enabled unl lock code disabled unlocked unl Menu lock code Up down selects current digit X moves to next digit 10c...

Page 9: ...d rise function to detect rapid rises in humidity when the ambient rH is under the threshold setting If a rapid rise is detected the fan will increase in speed proportionally between the trickle and b...

Page 10: ...errun duration of 5 minutes will take place This will override LS comfort mode boosting the fan immediately An activation when a Pullcord LS Light Switch boost is already active shall cancel overrun t...

Page 11: ...press of the Mode button will return the fan to the commissioning menu D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTE...

Page 12: ...us boost 1 with no trickle facility The fan is internally fused Fig 3 Continuous trickle with boost facility The fan is internally fused Fig 1 Continuous trickle with boost via pull cord The fan is in...

Page 13: ...facility SELV models Fig 6 Continuous trickle with boost facility via LS or internal pullcord SELV models Fig 4 Continuous trickle with pullcord boost SELV models N L 1 Phase Supply 220 240V 50Hz FUSE...

Page 14: ...g the controls Pull front panel as shown Loosen screws DO NOT REMOVE FROM GRILLE the screws are self retaining Pull inner grille away from housing as shown Open up the internal cover to access the spi...

Page 15: ......

Page 16: ...oduct rating label attached to the unit Has not been subjected to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUAR...

Reviews: