Standard settings:
Display
text
Configuration
Option
Selections
Default
r
‐
n
Rotate
display
r
‐
Y
=
display
rotated
r
‐
n
=
display
normal
r
‐
n
trI
Trickle
speed
adjustment
100mm:
0*,
5
to
30
l/s
(Max
limited
by
Boost
Selection)
9l/s
bSt
Boost
speed
adjustment
100mm:
6
to
35
l/s
(Min
limited
by
Trickle
Selection)
15
l/s
b15
Boost
Overrun
time
b0
to
b30
–
0
to
30
minutes
(0
disables
overrun)
15
h70
Humidity
level
trigger
h40
to
h90
‐
40%
to
90%
relative
humidity
70%
RH
F
‐
0
Fan
Control
Mode
F
‐
0
=
CV
disabled,
wall
/
window
installation
F
‐
1
=
CV
disabled,
ducted
installation
F
‐
2
=
CV
Constant
Volume
enabled
F
‐
0
c
‐
n
Comfort
mode
c
‐
n
=
normal
LS
overrun
c
‐
Y
=
comfort
mode
c
‐
n
unl
Enable
/
disable
lock
code
loc
‐
lock
code
enabled
unl
‐
lock
code
disabled
(unlocked)
unl
‐‐‐
Menu
lock
code
Up
/
down
selects
current
digit,
X
moves
to
next
digit.
10c
cod
To
change
the
lock
code
when
“cod”
is
displayed
select
the
up/down
buttons
to
select
a
digit
then
select
X
to
move
on
to
the
next
digit.
*If “0” is selected, the fan switches to Intermittent mode.
Advanced settings:
Display
text
Configuration
Option
Selections
Default
A
‐
Y
RH
Ambient
Response
A
‐
Y
Ambient
Response
enabled
A
‐
n
Ambient
Response
disabled
Enabled
P
‐
Y
RH
Rapid
Response
enable
p
‐
Y
=
Rapid
Response
enabled
p
‐
n
=
Rapid
Response
disabled
Y
Settings
Speed selection
Set trickle and boost speeds in l/s by using the and buttons.
To convert m3/h to l/s, divide the m3/h by 3.6 (e.g. 54m3/h / 3.6 = 15 l/s).