CONTINUOUS & INTERMITTENT EXTRACT FILTERLESS FAN  

 
Installation and Wiring Instructions 

 

Stock Ref. N° 

Revive 7 

 

473848 

Revive 7 SELV 

473849 

Revive 5  

 

473850 

Revive 5 SELV 

473851 

Revive 

 

473852 

Revive SELV  

473853 

Revive Intermittent  478367 
Revive SELV  

478368 

Intermittent

 

 

 

 

 

 

 

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. 
PLEASE SAVE THESE INSTRUCTIONS. 

 
 
 
 

 

Lo-Carbon 
Revive

 

 

IPX4 

220-240V~50Hz 

 

Summary of Contents for Lo-Carbon Revive

Page 1: ...N Revive 7 473848 Revive 7 SELV 473849 Revive 5 473850 Revive 5 SELV 473851 Revive 473852 Revive SELV 473853 Revive Intermittent 478367 Revive SELV 478368 Intermittent PLEASE READ INSTRUCTIONS IN CONJ...

Page 2: ...cting all poles having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with...

Page 3: ...NSFORMER SELV Models only 1 The transformer must not be installed in a shower cubicle or enclosure It must be sited away from direct sources of water spray and out of reach 1 5m of a person using a fi...

Page 4: ...dels only MUST be surface mounted to allow air to freely circulate around the unit When installed in a loft void it MUST NOT be enclosed or covered with insulation The fan is a class ll double insulat...

Page 5: ...ion type settings kitchen or bathroom and ducted or window wall The difference between bathroom and kitchen mode is shown above the boost speeds are higher for kitchen applications If the fan is insta...

Page 6: ...usted after commissioning as a pass code is required to access the menu This can be set in the menu to any 3 digit hexadecimal combination If the lock feature is enabled when a button is pressed the d...

Page 7: ...to move the display to the next data set Data Logger Menu When the display is rotated the decimal point will no longer display eg 055 represents 5 5KWh Data Examples Text scrolling from right to left...

Page 8: ...orated it could take up to 2 weeks for the humidity levels to stabilise Please leave the fan to dry out the room and after this period the fan should run normally ii The humidity set point could be se...

Page 9: ...1 with no trickle facility The fan is internally fused Fig 3 Continuous trickle with boost facility The fan is internally fused Fig 1 Continuous trickle with boost via pull cord The fan is internally...

Page 10: ...els Fig 6 Continuous trickle with boost facility via LS or internal pullcord SELV models Fig 4 Continuous trickle with pullcord boost SELV models N L 1 Phase Supply 220 240V 50Hz FUSE Switched Fused S...

Page 11: ...the screw at the bottom of the grille 2 Pull the grille clear of the screw and lift away Circuit board cover DO NOT REMOVE Control Board Display INCREASE Value REDUCE Value MODE Button Note Revive 7...

Page 12: ...to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your...