PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. 

PLEASE SAVE THESE INSTRUCTIONS 

 
 
 
 

Lo-Carbon 
SOLO Plus 

Centrifugal 
Bathroom/Toilet Fan

 

Stock Ref. N° 
 

427481B (P)

 

427482B (T)

 

427483B (HT)

 

427484B (TM)

 

 

Installation and Wiring Instructions 

 

 IPX4 

220-240V~50Hz 

 

Summary of Contents for Lo-Carbon Solo Plus HT

Page 1: ...ONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Lo Carbon SOLO Plus Centrifugal Bathroom Toilet Fan Stock Ref N 427481B P 427482B T 427483B HT 427484B TM Installation and Wiring Instr...

Page 2: ...provided with a local isolator switch capable of disconnecting all poles having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the ratin...

Page 3: ...igot Adaptor is firmly located onto the Base Housing and the shutter is still securely fastened and fully functional 4 Set up the appropriate speed selection and other features as outlined in Section...

Page 4: ...r grille but will be loose when the grille is ready to be removed Fig 1 Lift the inner grille from the bottom edge ensuring not to damage the sensor cable TM model only attached to the front assembly...

Page 5: ...E the Set Point turn the Humidity Adjuster H CLOCKWISE This makes the fan less sensitive to RH i e the fan will come on at a higher RH Fig 7 C WIRING WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MU...

Page 6: ...nsor lead must be disconnected Fig 2 Attaching the Spigot Fig 3 Surface mounting screw hole locations Fig 4 Converting outlet spigot for side exit and recess mounting Fig 6 PIR sensor cable TM only Fi...

Page 7: ...r adjuster T HT TM Models To reduce time Turn anti clockwise T To increase time Turn Clockwise Humidity adjuster HT Model To LOWER the set point Turn Anti clockwise To RAISE the set point Turn clockwi...

Page 8: ...8 Fig 9 T HT wiring diagram...

Page 9: ...ypology Control Factor CTRL 1 00 0 95 0 65 0 65 Control Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry o...

Page 10: ...ol Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage...

Page 11: ...11 Notes...

Page 12: ...glect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original sup...