background image

 

ORIGINAL INSTRUCTIONS 

 
READ AND SAVE THESE INSTRUCTIONS 

 

PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION. 
INSTALLATION AND WIRING INSTRUCTIONS SHOULD BE LEFT WITH END USER. 
  

Air moving equipment may present mechanical, electrical or noise hazards. To minimize 
risks associated with these potential hazards, it is essential that safety, installation, 
operation and maintenance instructions are followed. Implementation of these 
instructions should always be undertaken by technically competent personnel. 
  
Potential mechanical hazards must be eliminated by guarding against access to the 
rotating parts whilst the air moving equipment is operating. A range of guards are 
available for this purpose from Vent-Axia. 
  
Installation work, both mechanical and electrical, must be undertaken in accordance 
with the safety and installation instructions before switching on the unit. 
  
Maintenance work should not be attempted before first switching off and isolating the 
fan and its control from the electrical supply and ensuring that it cannot be accidentally 
turned back on again. It is essential to ensure that rotating parts have come completely 
to rest before maintenance work commences. 
  
Air moving equipment may generate unacceptable noise levels when in operation. It 
may be necessary to take appropriate action to reduce sound levels. A range of products 
are available for this purpose from Vent-Axia. 
 
This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities or lack of experience and knowledge unless they 
have been given supervision or instruction concerning use of this appliance by a person 
responsible for their safety. 
 
Young children should be supervised to ensure that they do not play with the appliance. 
  

IMPORTANT

 

 

 

1.  All electrical connections should be made by a properly qualified electrician. The fan 

must be sited and connected in accordance with current I.E.E Wiring Regulations, 
BS7671 (U.K.), or the appropriate standards in your country. 

  
2.  DO NOT use this appliance when the following are generated or present: Excessive 

grease or oil laden air, corrosive or flammable atmospheres. 

  
3.  When the fan is installed in a room containing a fuel burning appliance, the installer 

must ensure that the air replacement is adequate for both the fan and the fuel 
burning appliance. 

 
4.  If a fan is used to supply air into a room, the installer must ensure that the fan 

intake is located at least 600mm away from any flue outlet. 

  

Summary of Contents for MFQ35014

Page 1: ... used with this fan PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION THESE INSTRUCTIONS SHOULD BE LEFT WITH THE END USER Square Mixed Flow Fans MFQ MFQ35014 MFQ40014 MFQ45014 MFQ50014 MFQ40034 MFQ45034 MFQ50034 MFQ56034 MFQ56036 MFQ63034 MFQ63036 ...

Page 2: ...2 ...

Page 3: ...etely to rest before maintenance work commences Air moving equipment may generate unacceptable noise levels when in operation It may be necessary to take appropriate action to reduce sound levels A range of products are available for this purpose from Vent Axia This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of exper...

Page 4: ...units require a trial connection To change direction of rotation interchange any two phase supply leads 9 It is the responsibility of the installer to ensure that all aspects of system design are taken into consideration 10 Due to the weight of units it is recommended that at least two people are involved in the installation FAN MOUNTING 1 A duct mounted in line fan Short duct runs terminating clo...

Page 5: ...duct must be installed with Vent Axia overload relays or controls 5 Connect the power supply from the local isolator via any appropriate controls if fitted to the terminal box via the supplied cable gland using between 4 0mm and 7 0mm diameter cable Refer to the wiring diagrams and select the appropriate connections for the fan controller or other devices as being installed If in doubt please ask ...

Page 6: ...anger to safety or health then guards MUST be fitted Guards suitable for many applications are available from Vent Axia Ltd Please remember that fans need maintenance cleaning and inspection Allow for reasonable access for these operations to be carried out safely If in doubt please ask ROUTINE INSPECTION MAINTENANCE THIS MUST BE UNDERTAKEN BY A COMPETENT PERSON ISOLATE UNIT FROM ELECTRICAL SUPPLY...

Page 7: ...744 444703 10303106A 10314105A MFQ50014 444744 444705 10303110A 10314109A MFQ40034 444747 444700 Not available 10314302A MFQ45034 444747 444701 Not available 10314304A MFQ50034 444747 444702 Not available 10314304A MFQ56034 444747 444703 Not available 10314307A MFQ56036 444747 444701 Not available 10314304A MFQ63034 444747 444705 Not available 10314311A MFQ63036 444747 444702 Not available 1031430...

Page 8: ...8 Fig 2 Single phase MFQ Connected to a D O L Starter and an Auto Transformer Speed Controller with no TK connections Fig 3 Single phase MFQ Connected to an Electronic Speed Controller ...

Page 9: ...9 Fig 4 Three phase MFQ Connected to a D O L Starter Fig 5 Three phase MFQ Connected to an Auto Transformer Speed Controller ...

Page 10: ...10 Notes ...

Page 11: ...11 Notes ...

Page 12: ... Road Crawley West Sussex RH10 9JA SALES ENQUIRIES Tel 0844 8560590 Fax 01293 565169 TECHNICAL SUPPORT Tel 0844 8560593 Fax 01293 539209 For details of the warranty and returns procedure please refer to www vent axia com or write to Vent Axia Ltd Fleming Way Crawley RH10 9YX 409582B 0716 ...

Reviews: