background image

 

 

Installation and Wiring Instructions for the Solo Pro Range of Extractor Fans. 

 

  IMPORTANT: 
  READ THESE INSTRUCTIONS 
  BEFORE COMMENCING THE  
  INSTALLATION 

 
DO NOT install this product in areas where the following may be present or occur: 

  Excessive oil or a grease laden atmosphere. 

  Corrosive or flammable gases, liquids or vapours. 

• 

Ambient temperatures higher than 40°C or less than –5°C. 

• 

Possible obstructions which would hinder the access or removal of the Fan. 

 

SAFETY AND GUIDANCE NOTES 
A. 

All wiring to be in accordance with the current I.E.E. 
Regulations, or the appropriate standards of your country 
and 

MUST 

be installed by a suitably qualified person. 

B. 

The Fan should be provided with a local isolator switch 
capable of disconnecting all poles, having a contact 
separation of at least 3mm. 

C. 

Ensure that the mains supply (Voltage, Frequency, and 
Phase) complies with the rating label. 

D. 

The Fan should only be used in conjunction with the 
appropriate Vent-Axia products. 

E. 

The fan should only be used in conjunction with fixed wiring. 

F. 

When the Fan is used to remove air from a room containing 
a fuel-burning appliance, ensure that the air replacement is 
adequate for both the fan and the fuel-burning appliance. 

G. 

 The Fan should not be used where it is liable to be subject 
to direct water spray for prolonged periods of time. 

H. 

Where ducted Fans are used to handle moisture-laden air, a 
condensation trap should be fitted. Horizontal ducts should 
be arranged to slope slightly downwards away from the Fan. 

I. 

 This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental 
capabilities, or lack of experience and knowledge, unless they 
have been given supervision or instruction concerning use of 
the appliance by a person responsible for their safety. 

J. 

Young children should be supervised to ensure that they do 

not play with the appliance. 

Summary of Contents for Solo Pro HTP

Page 1: ...ation and Wiring Instructions Stock Ref N Solo Pro P 409159 Solo Pro T 409160 Solo Pro HTP 409161 Solo Pro TM 409162 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Solo Pro IPX4 220 240V 50Hz ...

Page 2: ... Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E The fan should only be used in conjunction with fixed wiring F When the Fan is used to remove air from a room containing a fuel burning appliance ensure that the air replacement is adequate for both the fan and the fuel burning appliance G The Fan should not be used where it...

Page 3: ...re the fan as described in Section B Wiring Adjust any settings as required see Section C Setup 8 Replace the PCB and inner covers and impeller 9 After installation ensure impeller rotates freely Replace the front panel WALL MOUNTING FIG 4 1 For wall mounting cut a 117mm diameter hole through the wall and insert the wall sleeve Slope the sleeve slightly downwards away from the fan Where necessary ...

Page 4: ... TIMER SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION 1 Remove the fan grilles and PCB cover The product is factory set at 15 minutes approx The overrun period can be adjusted from 3 25 minutes by altering the pot on the control PCB 2 To REDUCE the operating time use a small screwdriver to turn the pot ANTI CLOCKWISE 3 To INCREASE the operating time use a small screwdriver to turn the pot C...

Page 5: ...RD is switched into the off position the fan will deactivate The HTP model will return to the Auto sensing mode D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE 1 At intervals appropriate to the installation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Carefull...

Page 6: ...r 2 Remove the two screws as shown 3 For P and HTP models remove the pull cord clip L Switched Fused Spur 1 Phase Supply 220 240V 50Hz N L FUSE N N L 5 4 3 5A Fig 3 Solo Pro TM Visionex PIR Controller Please follow the fitting and wiring instructions for the Visionex PIR Controller for full installation instructions Solo Pro TM ...

Page 7: ... together to release the impeller 5 Remove two screws as shown Fig 5 Wiring and settings Supply cable via side or rear Supply cable connections Secure Supply cable with Cable Clamp Adjust Timer overrun or Humidistat set point model dependant as shown ...

Page 8: ...ogy Control Factor CTRL 1 00 0 95 0 65 0 65 Control Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs N A N A N A N A Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either supply or extract ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...lect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre by post or personal visit Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and pro...

Reviews: