background image

9.  The supply cable must be at the lower end of the heater if it is installed at an angle. 

10. Keep the supply cord away from the body of the heater as it will get hot during use. 

11. Do not install the heater on a flammable surface. 

12. Observe the minimum safe distance between the heater body and the flammable surfaces 

when mounted. 

13. The heater should always have a minimum clearance of 0.5m from a ceiling and adjacent 

wall. 

14. If the heater is to be used outside, The installing electrician will need to provide the 

appropriate rigid metallic, flexible or liquid tight conduit suitable to maintain an IP54 
installation. 

15. Before drilling ensure that there are no wires or water pipes in the area where the heater is 

to be installed. 

16. The heater must be installed on the mounting brackets provided. 

17. Fasten the brackets securely to the mounting surface and the backside of the heater using 

the nuts and screws supplied. 

18. Fasten the heater securely on the brackets using the nuts and bolts supplied. 

19. The brackets can be used to adjust the direction of the heater, adjust the heater angle by 

loosening the two bolts on the wall mounting bracket, and tighten the bolts again when the 
desired angle is reached. 

20. For bathrooms installation/s - the heater is to be installed so that switches and other 

controls cannot be touched by a person in the bath or shower. 

WIRING THE HEATER 

All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of 
your country and MUST be installed by a suitably qualified Electrician. The heater should be 
provided with a local isolator switch capable of disconnecting all poles, having a contact separation 
of at least 3mm. 

 

WARNING:

 THE HEATER AND ANCILLARY CONTROL EQUIPMENT 

MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE 
INSTALLATION / OR MAINTENANCE. 

IMPORTANT:-

 THIS HEATER MUST BE EARTHED 

Connecting the power supply cable to the mains (220V-240V ~ AC) 

220 V-240 V~ +10 % -10 % 50Hz Single phase power supply. Connect the power supply cable to 
the mains as follows: -  
Neutral (N) = Blue wire – Live (L)= Brown wire – Earth(      ) = Green and yellow wire. 

The wires must be connected

 in a suitable electrical connection box for the installation and must 

comply with the applicable standards.

 

DO NOT EXTEND CORD.

 

 

 

FUNCTION & OPERATION 

1. 

PRESS

 

the

 

power

 

button

 

on

 

the

 

right

 

hand

 

side

 

of

 

the

 

heater

 

ON.

 

The

 

heater

 

will

 

turn

 

ON

 

2. 

PRESS

 

the

 

power

 

button

 

on

 

the

 

right

 

hand

 

side

 

of

 

the

 

heater

 

OFF.

 

The

 

heater

 

will

 

turn

 

OFF.

 

 

Summary of Contents for SUNB3000BL

Page 1: ...nk you for purchasing this quality Heater To ensure correct function and safety please read all instructions before using the product and keep all instructions for future reference WARNING When using...

Page 2: ...ND RETAINED FOR FUTURE REFERENCE We cannot be liable for any damages caused by failure to observe these instructions IMPORTANT 1 Read all instructions before using this heater 2 Remove the unit from i...

Page 3: ...ght conduit suitable for an IP54 rated installation Never extend the supplied cord 14 Do not allow cord to overhang the counter top where it can be easily pulled by children 15 Do not put fingers or f...

Page 4: ...thing that may cause blockage Check all inlets and outlets from time to time to ensure it is clear of any dirt or dust accumulation DO NOT COVER 24 Do not use it in areas where gasoline paint or flamm...

Page 5: ...h the reflector of the heater or that it does not trail into heated areas The supply cable can be fixed to the metal mounting bracket behind the heater with plastic zip ties 1 This heater must be perm...

Page 6: ...n the wall mounting bracket and tighten the bolts again when the desired angle is reached 20 For bathrooms installation s the heater is to be installed so that switches and other controls cannot be to...

Page 7: ...1 Make sure the heater is always switched off before cleaning 2 Check the Reflector and IR Filament for dirt dust or contaminants at least once a month If necessary apply cleaning and maintenance pro...

Page 8: ...4 Do not touch the heating element with bare fingers as residue from your hand could affect the life of the lamp If it is accidentally touched remove the finger marks with a soft cloth moistened with...