9. The supply cable must be at the lower end of the heater if it is installed at an angle.
10. Keep the supply cord away from the body of the heater as it will get hot during use.
11. Do not install the heater on a flammable surface.
12. Observe the minimum safe distance between the heater body and the flammable surfaces
when mounted.
13. The heater should always have a minimum clearance of 0.5m from a ceiling and adjacent
wall.
14. If the heater is to be used outside, The installing electrician will need to provide the
appropriate rigid metallic, flexible or liquid tight conduit suitable to maintain an IP54
installation.
15. Before drilling ensure that there are no wires or water pipes in the area where the heater is
to be installed.
16. The heater must be installed on the mounting brackets provided.
17. Fasten the brackets securely to the mounting surface and the backside of the heater using
the nuts and screws supplied.
18. Fasten the heater securely on the brackets using the nuts and bolts supplied.
19. The brackets can be used to adjust the direction of the heater, adjust the heater angle by
loosening the two bolts on the wall mounting bracket, and tighten the bolts again when the
desired angle is reached.
20. For bathrooms installation/s - the heater is to be installed so that switches and other
controls cannot be touched by a person in the bath or shower.
WIRING THE HEATER
All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of
your country and MUST be installed by a suitably qualified Electrician. The heater should be
provided with a local isolator switch capable of disconnecting all poles, having a contact separation
of at least 3mm.
WARNING:
THE HEATER AND ANCILLARY CONTROL EQUIPMENT
MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE
INSTALLATION / OR MAINTENANCE.
IMPORTANT:-
THIS HEATER MUST BE EARTHED
Connecting the power supply cable to the mains (220V-240V ~ AC)
220 V-240 V~ +10 % -10 % 50Hz Single phase power supply. Connect the power supply cable to
the mains as follows: -
Neutral (N) = Blue wire – Live (L)= Brown wire – Earth( ) = Green and yellow wire.
The wires must be connected
in a suitable electrical connection box for the installation and must
comply with the applicable standards.
DO NOT EXTEND CORD.
FUNCTION & OPERATION
1.
PRESS
the
power
button
on
the
right
hand
side
of
the
heater
ON.
The
heater
will
turn
ON
2.
PRESS
the
power
button
on
the
right
hand
side
of
the
heater
OFF.
The
heater
will
turn
OFF.