PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)                 No 1254/2014) 

 
 
 
 

 

 

 

Name:

  

Vent

Axia

 

Vent

Axia

 

Model

 

ID

 

(Stock

 

Ref.)

 

:

 

VA

 

150

 

P

 ‐ 

152110

 

VA

 

150

 

A

 ‐ 

153110

 

SEC

 

Class

 

F

 

F

 

SEC

 

Value

 

('Average')

 

13.97

 

13.97

 

SEC

 

Value

 

('Warm')

 

6.32

 

6.32

 

SEC

 

Value

 

('Cold')

 

27.32

 

27.32

 

Label

 

Required?

 

(Yes/No=Out

 

of

 

scope)

 

No

 

No

 

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

 

RVU

UVU

 

RVU

UVU

 

Speed

 

Drive

 

Multi

Speed

 

Multi

Speed

 

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

 

None

 

None

 

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

 

N/A

 

N/A

 

Max.

 

Flow

 

Rate

 

(m3/h)

 

216.00

 

216.00

 

Max.

 

Power

 

Input

 

(W):

 

(@Max.Flow

 

Rate)

 

19.00

 

19.00

 

LWA:

 

Sound

 

Power

 

Level

 

(dB)

 

54.52

 

54.52

 

Ref.

 

Flow

 

Rate

 

(m3/s)

 

0.04

 

0.04

 

Ref.

 

Pressure

 

Diff.

 

(Pa)

 

N/A

 

N/A

 

SPI

 

[W/(m3/h)]

 

0.13

 

0.13

 

Control

 

Factor

 

&

 

Control

 

Typology:

 

(CTRL/

 

Typology)

 

  

  

Control

 

Factor;

 

CTRL

 

1.00

 

1.00

 

Control

 

Typology

 

Manual

 

Control

 

Manual

 

Control

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                                                  

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

 

N/A

 

N/A

 

Mixing

 

Rate

 

of

 

Non

Ducted

 

BVUs

 

not

 

intended

 

to

 

be

 

equipped

 

with

 

one

 

duct

 

connection

 

on

 

either

 

supply

 

or

 

extract

 

air

 

side;

 

N/A

 

N/A

 

Position

 

and

 

description

 

of

 

visual

 

filter

 

warning

 

for

 

RVUs

 

intended

 

for

 

use

 

with

 

filters,

 

including

 

text

 

pointing

 

out

 

the

 

importance

 

of

 

regular

 

filter

 

changes

 

for

 

performance

 

and

 

energy

 

efficiency

 

of

 

the

 

unit

 

N/A

 

N/A

 

For

 

UVUs

 

(Instructions

 

Install

 

Regulated

 

Supply/Extract

 

Grilles

 

Façade)

 

In

 

F&W

 

In

 

F&W

 

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

 

www.vent

axia.com

 

www.vent

axia.com

 

Sensitivity

 

p.

 

Var20/

20

 

Pa:

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

Air

 

Tightness

ID/OD

(m3/h)

 

(for

 

Non

Ducted

 

Vus)

 

N/A

 

N/A

 

Annual

 

Electricity

 

Consumption:

 

AEC

 

(kWh/a)

 

1.73

 

1.73

 

Annual

 

Heating

 

Saved:

 

AHS

 

(kWh/a)

 

  

  

AHS:

 

Average

 

13.97

 

13.97

 

AHS:

 

Warm

 

6.32

 

6.32

 

AHS:

 

Cold

 

27.32

 

27.32

 

Summary of Contents for VA 150 A

Page 1: ...TIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Installation and Wiring Instructions 220 240V 1 50Hz VA150 A STOCK Ref 153110B VA150 P STOCK Ref 152110B VA 150 A VA 150 P WINDOW...

Page 2: ...2...

Page 3: ...ate standards of your country and MUST be installed by a suitably qualified person B The Fan should be provided with a local all pole isolator switch having a contact separation of at least 3mm C Ensu...

Page 4: ...s with a fixing thickness up to 32mm with the screws provided When fixing thickness exceeds 32mm the unit should be secured with Extended Fixing Rods available as an accessory item 56 81 04 If the uni...

Page 5: ...catches D4 Lift off the housing D5 Remove the top cover from its housing Check rating label to ensure that the fan unit is the correct voltage D6 Ease back the motor support safety catch located in th...

Page 6: ...er lugs and around the spigot E2 From the outside place the exterior grille assembly over the projecting spigot ensure that the grille louvers are slanting downwards E3 From the inside insert the four...

Page 7: ...internal grille Locate the bottom edge first and then engage the top Tighten the securing screw at the top of the grille E8 Switch on the mains supply Check the fans operation VA150 P 1 Pull the pullc...

Page 8: ...e through the clamp 2 Connect the LIVE Brown to the terminal L and NEUTRAL Blue to the terminal N 3 Tighten the cable clamp screws evenly ensuring a secure grip on the outer sheath of the cable The Fa...

Page 9: ...trol Typology Manual Control Manual Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs N A N A Mixing R...

Page 10: ...10...

Page 11: ...11...

Page 12: ...rge provided that the product 1 Has been installed and used in accordance with the instruction given with each unit 2 The electricity supply complies with the rating label 3 Has not been misused negle...

Reviews: