DESCRIPTION

 

The VA100 SELV 12 range from Vent-Axia is a 100mm extract fan for domestic bathrooms and WC’s available 
as window, wall or panel mounted models. Model options with shutter, timer and auto humidity control. 
 

ACCESSORIES

 (not supplied)  

 
A range of 100mm wall and window kits are available for  
installing into most walls/windows using telescopic 
liners/spacers supplied.  
 

A. INSTALLATION 
 
 
SITING THE CONTROLLER 

1. 

The controller must not be installed in a shower cubicle or enclosure. It must be sited away from direct 
sources of water spray and out of reach (1.5m) of a person using a fixed bath or shower. 

2. 

Site away from direct sources of heat. Ambient temperature range 0 to 40ºC. Do not site in an area 
containing excessive levels of grease. 

3. 

Decide where to site the controller and fan (see section siting the fan), and work out the required cable 
runs. 

 
 
SITING THE FAN 

1.  

The electrical supply to this fan is 12V AC SELV from the mains controller. This means that the fan 
may be installed within reach of a person using a fixed bath or shower, i.e. in a nearby wall or window.  
However, the fan must not be placed where it could be submerged in water or regularly exposed to 
direct water spray, e.g. from a shower head whether permanently fixed or movable. 

2.  

Site away from direct sources of heat. Ambient temperature range 0 to 40ºC. Do not site in an area 
containing excessive levels of grease. 

3.  

If the fan is installed in a room containing a fuel burning appliance the installer must ensure that air 
replacement is adequate for both the fan and the fuel burning appliance. If the fan is used to supply air 
into the room the installer must ensure that the fan intake is located at least 600mm away from any flue 
outlet. 

4.   

Ducted Applications. These fans can be used with short lengths of rigid ducting, but check details first 
with your Vent-Axia sales centre. Where an excessive amount of moisture is present in the air, a 
condensation trap will need to be installed in the exhaust duct. Horizontal ducts should slope away 
from the fan unit. Ducts passing through an unheated roof void should be insulated. 

5.  

A short circuit of the airflow should always be avoided by siting the fan as far away as possible from 
and opposite to the main source of air replacement. FIG.1 

6.   

VA100SVLH, VA100SVXH and VA100SVXHT. These models are fitted with automatic electronic 
humidity sensing. The humidity sensor needs free air circulation so do not site close to cupboards, etc. 
Do not site above a radiator or other heat source. 

 
 
PANEL/CEILING MOUNTING 
IMPORTANT:

 The fan should be installed into a closed duct system or protected by an exterior air grille.

 

1.   

Cut a 105mm diameter hole in the fixing surface. 

2.   

Remove the grille by loosening the screw at the bottom of the grille.  

3.   

Mark the screw centres through the holes in the fan back plate. Drill, plug and screw into position. 

4.   

Replace grille and tighten the screw.  

 
 
 

Summary of Contents for VA100

Page 1: ...2 25 84 10E VA100SVLH12 25 81 12E VA100SVXH12 25 83 12F VA100SVXHT12 25 85 12C PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS VA100 SELV 12 RANGE FAN UNITS 1...

Page 2: ......

Page 3: ...only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan connector terminals is made with flexible cable F The transformer controller shou...

Page 4: ...exposed to direct water spray e g from a shower head whether permanently fixed or movable 2 Site away from direct sources of heat Ambient temperature range 0 to 40 C Do not site in an area containing...

Page 5: ...n 4 Repeat for the external grille sub frame Fix exterior grille into position with the louvres positioned downwards AFTER INSTALLATION ENSURE IMPELLER ROTATES FREELY B WIRING WARNING THE FAN AND ANCI...

Page 6: ...sible that the humidity controller will make the fan run continuously until it has acclimatised to the environment As part of the installation process it is important to set adjust the humidity sensit...

Page 7: ...FUSE Switched Fused Spur N 2 1 Controller L Fan SELV Supply 12V 50Hz Pullcord L N 3A UK LS N L N Fan Controller LS L N SELV Supply 12V 50Hz 3A UK Ls LS 0 12V N L 1 Phase Supply 220 240V 50Hz FUSE Swit...