provide full disconnection under over voltage category III, the
instructions state that means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.
L.
Ensure the grille is fully engaged onto the fan chassis using all
clips.
ACCESSORIES
(not supplied)
WALL FITTING KIT
A range of 100mm wall kits are available for installing into most walls using telescopic liners
supplied.
WINDOW FITTING KIT
For use in single or sealed
double glazing and most
materials up to 40mm thick.
INSTALLATION
IMPORTANT:
The fan should only be used in
conjunction with fixed wiring.
PANEL/CEILING MOUNTING
1.
For panel/ceiling mounting the fan should be
installed into a closed duct protected by an
exterior air grille that must comply with the
standard requirements of your country to
prevent access to the fans impeller.
2.
Cut a 105mm diameter hole for 100mm fans.
3.
Push the two clips on the bottom of the fan
and pull the grille away from the chassis.
4.
Using the built in spirit level bubble as an
aid. Mark the screw centres through the
holes in the fan back plate. Drill, plug and
screw into position.
5.
After installation, ensure impeller rotates
freely and the shutters can open.
6.
Replace the grille and ensure the clips
reactivate.
WALL MOUNTING
1.
For wall mounting either cut a 115mm diameter hole for 100mm fans, through the wall and insert the
wall sleeve. Slope the sleeve slightly downwards away from the fan. Cut to length and cement both
ends into position flush with the wall faces.
2.
Push the two clips on the bottom of the fan and pull the grille away from the chassis.
3.
Using the built in spirit level bubble as an aid. Mark the screw centres through the holes in the fan
back plate. Drill, plug and screw into position. Fix exterior grille into position with the louvres
positioned downwards. (Note:- The grille must comply with the standard requirements of your
country to prevent access to the fans impeller. The wall kit used in this installation should provide a
minimum ducting length of 100mm from the fans back plate to the inside of the external grille).
4.
After installation, ensure impeller rotates freely and the shutters can open.
5.
Replace the grille and ensure the clips reactivate.
Stock Reference
White
Brown
Wall Fitting Kit
100mm 254102 254100
Window Fitting Kit
100mm 442947 -
Open up the internal cover to access
the spirit level bubble
Spirit level used
only for cosmetic
help. Not
essential for the
normal working of