WIRING

 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST 
BE ISOLATED FROM THE POWER SUPPLY DURING THE 
INSTALLATION / OR MAINTENANCE

 

IMPORTANT 

  The fan should only be used in conjunction with fixed wiring.  

  The cross - sectional area of supply cord used should be ranged from 0.75-1.5mm

2

  Cable entry can be made from the rear or the side of the fan using the grommet provided. 

  The extraction fan is suitable for connection to 220-240V ~ 50Hz supply.  

  The fan is a class ll double insulated product and 

MUST NOT 

be earthed. 

 

 

1.  Select and follow the appropriate wiring diagram. (Fig. 1 or 2) 
2.  Check all connections have been made correctly and ensure all terminal connections are securely 

fastened. 

3.  Ensure the impeller rotates and is free from obstructions. 

 
SETUP 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE 
ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR 
MAINTENANCE. 
 

Fixed Speed Range

 – Fig1, 2, 3, 4, 5 & 6 

 

VASF100BO

 – Basic - Remote or light switch operation. 2 Speed options selectable at install. 

VASF100TO

 – Timer* - Overrun timer adjustable 5-30min. 2 Speed options selectable at install. 

VASF100HTO

 - 

Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. 2 Speed option 

selectable at install. 

VASF100PIRO

 - PIR* - Motion detection, presence infrared motion control with overrun timer adjustable  

5-30min. Single speed. 
 

Lo-Carbon Variable Speed Range

 – Fig1, 2, 3 & 7 

 

VASF100BVO

 – Basic - Remote or light switch operation. Variable speed options selectable at install. 

VASF100TVO

 – Timer* - Fixed 15min. timer overrun. Variable speed options selectable at install. 

VASF100HTVO

 - Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. Variable speed 

options selectable at install. 

 

Lo-Carbon Continuous Running Range

 – Fig2, 3 & 7 

 

VASF100TCO

 – Timer* - Fixed 15min. overrun timer. Continuous running fan with variable speed options. 

VASF100HTCO

 - Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. Continuous 

running fan with variable speed options. 
 

*All timer versions require a third switch live wire for the timer to work. 
 
 
 
 

Summary of Contents for VASF100BO

Page 1: ...ASE SAVE THESE INSTRUCTIONS Silent Fan Open Fronted Range 220 240V 50Hz Fixed Speed Models Stock Ref N 495697 VASF100BO 495698 VASF100TO 495699 VASF100HTO 495705 VASF100PIRO Lo Carbon Models Stock Ref...

Page 2: ...supply Voltage Frequency and Phase complies with the rating label E The Fan should only be used in conjunction with the appropriate Vent Axia products F The Fan should only be used in conjunction with...

Page 3: ...ubble as an aid Mark the screw centres through the holes in the fan back plate Drill plug and screw into position 5 After installation ensure impeller rotates freely and the shutters can open 6 Replac...

Page 4: ...4 5 6 VASF100BO Basic Remote or light switch operation 2 Speed options selectable at install VASF100TO Timer Overrun timer adjustable 5 30min 2 Speed options selectable at install VASF100HTO Humidity...

Page 5: ...be inspected and cleaned to ensure there is no build up of dirt or other deposits 2 Wipe the inlets and front face with a damp cloth until clean The fan has sealed for life bearings which do not requi...

Page 6: ...LOCKWISE Speed Selection JP5 Change the jumper connector to the position shown for the desired speed High Speed Low Speed Timer Adjustment Timer Adjustment To REDUCE the operating time use a small scr...

Page 7: ...inbuilt humidity sensor automatically adjusts dependant on ambient conditions and does not need adjusting Speed Selection Adjust the fan speed by turning the pot clockwise to increase and anti clockw...

Page 8: ...ears and the Lo Carbon products for 5 years from date of purchase against faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Com...

Reviews: