WIRING
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST
BE ISOLATED FROM THE POWER SUPPLY DURING THE
INSTALLATION / OR MAINTENANCE
.
IMPORTANT
The fan should only be used in conjunction with fixed wiring.
The cross - sectional area of supply cord used should be ranged from 0.75-1.5mm
2
.
Cable entry can be made from the rear or the side of the fan using the grommet provided.
The extraction fan is suitable for connection to 220-240V ~ 50Hz supply.
The fan is a class ll double insulated product and
MUST NOT
be earthed.
1. Select and follow the appropriate wiring diagram. (Fig. 1 or 2)
2. Check all connections have been made correctly and ensure all terminal connections are securely
fastened.
3. Ensure the impeller rotates and is free from obstructions.
SETUP
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE
ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR
MAINTENANCE.
Fixed Speed Range
– Fig1, 2, 3, 4, 5 & 6
VASF100BO
– Basic - Remote or light switch operation. 2 Speed options selectable at install.
VASF100TO
– Timer* - Overrun timer adjustable 5-30min. 2 Speed options selectable at install.
VASF100HTO
-
Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. 2 Speed option
selectable at install.
VASF100PIRO
- PIR* - Motion detection, presence infrared motion control with overrun timer adjustable
5-30min. Single speed.
Lo-Carbon Variable Speed Range
– Fig1, 2, 3 & 7
VASF100BVO
– Basic - Remote or light switch operation. Variable speed options selectable at install.
VASF100TVO
– Timer* - Fixed 15min. timer overrun. Variable speed options selectable at install.
VASF100HTVO
- Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. Variable speed
options selectable at install.
Lo-Carbon Continuous Running Range
– Fig2, 3 & 7
VASF100TCO
– Timer* - Fixed 15min. overrun timer. Continuous running fan with variable speed options.
VASF100HTCO
- Humidity Timer* - Humidity controlled with fixed 15min. timer overrun. Continuous
running fan with variable speed options.
*All timer versions require a third switch live wire for the timer to work.