background image

Page 

THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE.

PARTS FOR VENT-A-HOOD PRODUCTS

MOTORS

PART NO.

DESCRIPTION

PRICE

P1301-1

SINGLE SPEED WHITE MOTOR (CW)

P1301-2

TWO SPEED WHITE MOTOR (CW)

P1302-1

BLACK MOTOR (CCW)

P1315

K SERIES MOTOR

P1900

ADAPTER (AMP PLUG/TWO PRONG PLUG)

BLOWER WHEELS

PART NO.

DESCRIPTION

PRICE

P1305

WHITE BLOWER WHEEL (CW)

P1306

BLACK BLOWER WHEEL (CCW)

P1307

K SERIES BLOWER WHEEL

BLOWER HOUSINGS

PART NO.

DESCRIPTION

PRICE

SPECIFY HOOD COLOR

P1029

B100/T200 BLOWER HSG w/DAMPER

P1029E

B100/T200 EZ CLEAN HSG w/DAMPER

P1028

B200/T400 BLOWER HSG w/DAMPERS

P1028E

B200/T400 EZ CLEAN HSG w/DAMPERS

P1030

T200 REVERSE BLOWER HSG w/DAMPER

P1030E

T200 REVERSE EZ CLEAN HSG w/DAMPER

P1021

K SERIES BLOWER COVER (PAN)

BLOWER SHIELDS

PART NO.

DESCRIPTION

PRICE

P1025

B100/T200 SHIELD (ENAMEL)

P1025E

B100/T200 EZ CLEAN SHIELD (ENAMEL)

P1027

B100/T200 SHIELD (STAINLESS)

P1027E

B100/T200 EZ CLEAN SHIELD (STAINLESS)

P1024

B200/T400 SHIELD (ENAMEL)

P1024E

B200/T400 EZ CLEAN SHIELD (ENAMEL)

P1026

B200/T400 SHIELD (STAINLESS)

P1026E

B200/T400 EZ CLEAN SHIELD (STAINLESS)

P1610P

NICKEL SHIELD SCREW

SWITCHES AND CONTROLS

PART NO.

DESCRIPTION

PRICE

P1430

SWITCH FOR SINGLE SPEED WHITE MOTOR

P1431

SWITCH FOR SINGLE SPEED BLACK MOTOR

P1432

SWITCH FOR FLUORESCENT LIGHT

P1433

SWITCH FOR TWO SPEED WHITE MOTOR

P1434

SWITCH FOR HALOGEN LIGHTS

P1409

MOMENTARY SWITCH (TILT/TLH HOODS)

P1418

DIMMER SWITCH (CAN LIGHTS)

P1419

ROTARY SWITCH (HEAT LIGHTS)

P1422

KNOB FOR ROTARY SWITCH (SET SCREW)

P1425

REMOTE BLOWER SPEED CONTROL (HOOD)

M LINE COMPONENTS

PART NO.

DESCRIPTION

PRICE

P1440

M LINE BLOWER SWITCH

P1445

M LINE BLOWER SWITCH KNOB

P1450

M LINE LIGHT SWITCH

P1455

M LINE LIGHT SWITCH KNOB

P1456

M600 WIRING HARNESS

P1457

M1200 WIRING HARNESS

LIGHT BULBS

PART NO.

DESCRIPTION

PRICE

P1110

GU10 HALOGEN BULB, 50 WATT

P1120

F15/T8 FLUORESCENT BULB, 15 WATT

P1130

PAR20 HALOGEN BULB, 50 WATT

LIGHT FIXTURE COMPONENTS

PART NO.

DESCRIPTION

PRICE

P1101

SP2 BALLAST (NEWER HOODS)

P1103

LEFT LAMPHOLDER

P1104

RIGHT LAMPHOLDER

P1105

FS-2 STARTER

P1106

STARTER SOCKET

P1122

HEAT LAMP SOCKET

P1123

PAR20 HALOGEN LAMP SOCKET

P1124

GU10 HALOGEN LAMP SOCKET

COMPLETE FLUORESCENT LIGHT FIXTURES

PART NO.

DESCRIPTION

PRICE

INCLUDES 18” FLUORESCENT BULB (P1120)
SPECIFY MODEL, COLOR, AND SIZE OF HOOD
NOT AVAILABLE IN STAINLESS STEEL, USE GUNSMOKE

P1016

3” LIGHT BOX (WALL MOUNT & ISLAND)

P1018

2” LIGHT BOX (UNDER CABINET)

PxxxB

FIXTURE WITH BACK, ADD

P1127

FLUORESCENT LIGHT DIFFUSER

REPLACEMENT FILTERS

PART NO.

DESCRIPTION

PRICE

P1501

CV FILTER (11-1/2” DIA. X 4-1/2”T)

P1502A

MESH (16” x 20” x 2”)

P1502B

MESH (10” x 20” x 2”)

P1506

SS BAFFLE (16” x 20” x 1-1/2”)

P1506A

SS BAFFLE (10” x 20” x 1-1/2”)

P1530

M LINE BAFFLE FILTER

BACK DRAFT DAMPERS

PART NO.

DESCRIPTION

PRICE

P1031

NYLON POLYMER DAMPER

P1040

B100/T200 METAL DAMPER

P1041

B200 METAL DAMPER

P1042

K SERIES DAMPER

REMOTE BLOWER COMPONENTS

PART NO.

DESCRIPTION

PRICE

P1425

REMOTE BLOWER SPEED CONTROL (HOOD)

P1510

RM1000 BLOWER WHEEL

P1515

RM1000 MOTOR

P1520

RM1500 BLOWER WHEEL

P1525

RM1500 MOTOR

OTHER MISCELLANEOUS ITEMS

PART NO.

DESCRIPTION

PRICE

P1039

FLAP STAY FOR TILT/TLH HOODS

AW101

T-HANDLE, 1/8” ALLEN WRENCH

AW102

STANDARD, 1/8” ALLEN WRENCH

P1424

SENSASOURCE THERMOSTAT ASSY

SS KIT

STAINLESS STEEL SCRATCH REPAIR KIT

SS64

STAINLESS STEEL MAGIC (CAN)

CP101

RED BEAR® COPPER POLISH

P1316

3-1/4” x 10” COLLAR FOR K SERIES

P1317

BACK PLATE FOR K SERIES

email: customer_service@ventahood.com

website: www.ventahood.com

4/16/2012 Rev. 1

Summary of Contents for DAH18

Page 1: ... CFM B200 Dual Blower Top View Electrical Mechanical Specifications For Blower Units Model Volts Amps Hz RPM CFM SP 0 0 Equivalent CFM CFM SP 0 1 CFM SP 0 2 CFM SP 0 3 Minimum Round Duct Size Sones B100 Single 115 3 5 60 1550 300 450 273 245 225 6 28 in 2 5 4 B200 Dual 115 5 5 60 1550 600 900 531 480 430 8 50 in 2 6 5 B200 Dual B100 Single 115 8 0 60 1550 900 1350 804 725 655 VP562 10 79 in 2 6 3 ...

Page 2: ...all or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Prote...

Page 3: ...0 B200 10 round or equivalent 79 sq in VP562 Optional Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Optional Ducting Requirements NEVER reduce the duct size When combining ducts together the square inch area must reflect the total square inch area of the ducts being combined Do not use flexible or corrugated duct This type of duct will restrict airflow and reduce performance Only use ...

Page 4: ... the location of the exhaust outlet s on the top of the hood allowing room for the transition if applicable If a transition is used install duct down to the location of the transition outlet plus 1 This will allow the transition to engage 1 inside of duct Method 2 Install the duct s from the outside of the home to the ceiling over the exhaust outlet s on the hood The end of the duct s should exten...

Page 5: ...all where it will hang 6 Remove the shipping tape that is securing the E Z Clean shield s inside the hood Remove the E Z Clean shield s by lightly pulling it toward the front of the hood Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches one on each side of the housing The housing s should be pulled forward and gently tippe...

Page 6: ...ting strip to at least two wall studs 12 FOR BACK VENTING APPLICATIONS ONLY IF NOT BACK VENTING PROCEED DIRECTLY TO STEP 13 Note Wall studs may interfere with back venting installations Additional framing may be required It is necessary to cut duct access hole s in the wall prior to installing the hood Method 1 Hold the hood on the mounting strip by aligning the channel at the top of the back of t...

Page 7: ...nstalling the screws previously removed from the strip in Step 11 into the pilot holes drilled in Step 13 Use duct tape to seal joints Insert the electrical wire from the service panel into the electrical wire clamp on each motor box Tighten the wire clamp s If applicable slide the duct cover between the ceiling and the top of the hood back to the wall and attach the duct cover to the hood through...

Page 8: ...23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL D...

Page 9: ...unt EPT NEPT SEPT C n a n a n a VP513 VP515 or VP561 n a 30 Tall Wall Mount C n a VP513 VP515 or VP561 VP513 VP515 or VP561 2 VP515 or 2 VP561 CWH B n a VP513 VP515 or VP561 VP513 VP515 or VP561 2 VP515 or 2 VP561 TILT Out TLH C n a VP513 VP561 n a n a JCH A1 Designer Series D n a VP513 VP515 or VP561 VP513 VP515 or VP561 2 VP515 or 2 VP561 JCH B1 Designer Series D n a VP513 VP515 or VP561 VP513 V...

Page 10: ...ew VP513 6 Round VP515 8 Round VP561 8 Round to 6 x 8 1 2 Rectangular 8 Round Diagram D Off the Top Within the Duct Cover Drawing Not To Scale Side View VP513 6 Round VP515 8 Round VP561 8 Round to 6 x 8 1 2 Rectangular 8 Round VP559 3 1 4 x 10 Rectangular VP561 8 Round to 6 x 8 1 2 Rectangular 7 Tall VP559 3 1 4 x 10 4 1 4 Tall VP513 6 Round 8 1 2 Tall When Fully Adjusted to 90 Degrees VP515 8 Ro...

Page 11: ...he KHSLD Liner Insert all Vent A Hood range hoods duct out the top and can be back vented only by use of transitions and or elbows Transition Heights VP559 3 1 4 x 10 Rectangular 4 1 4 Tall VP513 6 Round 8 1 2 Tall When Adjusted To 90 Degrees VP515 8 Round 10 3 4 Tall When Adjusted To 90 Degrees VP561 8 Round To 6 x 8 1 2 Rectangular 7 Tall K Series With VP559 Installed Back View B100 Blower Outle...

Page 12: ...nge Hood and the KHSLD Liner Insert all Vent A Hood range hoods duct out the top and can be back vented only by use of transitions and or elbows Transition Heights VP513 6 Round 8 1 2 Tall When Adjusted To 90 Degrees VP515 8 Round 10 3 4 Tall When Adjusted To 90 Degrees VP561 8 Round To 6 x 8 1 2 Rectangular 7 Tall B300 Blower Outlets With VP513 And VP561 Installed Back View B300 Blower Outlets Wi...

Page 13: ... Cabinet Range Hood and the KHSLD Liner Insert all Vent A Hood range hoods duct out the top and can be back vented only by use of transitions and or elbows Transition Heights VP513 6 Round 8 1 2 Tall When Adjusted To 90 Degrees VP515 8 Round 10 3 4 Tall When Adjusted To 90 Degrees VP561 8 Round To 6 x 8 1 2 Rectangular 7 Tall B400 Blower Outlets With 2 VP561s Installed Back View B400 Blower Outlet...

Page 14: ...ound VP527 7 Round VP528 8 Round MODEL DESCRIPTION PRICE VP554 10 Round MODEL DESCRIPTION PRICE VP555 12 Round MODEL DESCRIPTION PRICE VP538 6 x 8 1 2 VP560 3 1 4 x 10 MODEL DESCRIPTION PRICE VP539 6 Round VP540 7 Round VP541 8 Round MODEL DESCRIPTION PRICE VP552 10 Round VP553 12 Round MODEL DESCRIPTION PRICE VP539 HP 6 Round VP540 HP 7 Round VP541 HP 8 Round MODEL DESCRIPTION PRICE VP552 HP 10 R...

Page 15: ... BLOWER SWITCH KNOB P1450 M LINE LIGHT SWITCH P1455 M LINE LIGHT SWITCH KNOB P1456 M600 WIRING HARNESS P1457 M1200 WIRING HARNESS LIGHT BULBS PART NO DESCRIPTION PRICE P1110 GU10 HALOGEN BULB 50 WATT P1120 F15 T8 FLUORESCENT BULB 15 WATT P1130 PAR20 HALOGEN BULB 50 WATT LIGHT FIXTURE COMPONENTS PART NO DESCRIPTION PRICE P1101 SP2 BALLAST NEWER HOODS P1103 LEFT LAMPHOLDER P1104 RIGHT LAMPHOLDER P11...