background image

Page 3

L108 1213A

Installation Details

1)  Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard liners only. 

Custom liners may require additional specification consideration.

2)  When installing a SLD wall mount liner (19 1/4” deep), it is recommended that the bottom edge of the liner be located 

no more than 24” - 27” above the cooking surface for optimum performance. For PSLD and PSLB wall mount liners (22 

1/2” deep), it is recommended that the bottom edge of the liner be located no more than 27” - 30” above the cooking 

surface for optimum performance. For custom liners, the recommended height off the cooking surface is dependent 

on the depth of the liner. In general, the deeper the custom liner, the higher off the cooking surface it can be, up to a 

maximum recommended height of 30”above the cooking surface for optimum performance.

3)  Install the duct(s) from the outside of the home down to the location of the exhaust outlet(s) on the top of the liner 

allowing room for the transition (if applicable). If back venting, the elbow(s) should be installed so that the non-crimped 

end(s) are on the inside the collar(s) of the exhaust outlet(s). If a transition is used, install duct down to the location of 

the transition outlet plus 1”. This will allow the transition to engage 1” inside of duct. Consult the connection diagrams 

(next page) for further details on exhaust outlet placement.

 

Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is included on the back 

page of this instruction sheet.

 

Transition heights are as follows:

 

Single Blower (B100): 

6” round duct will connect directly to the top of the liner.

Dual Blower (B200): 

8” round duct will connect directly to the top of the liner.

Single and Dual Blower (B100 & B200):  6” round duct will connect directly to the top of the hood; 8” round will 

connect directly to the top of the hood. Optional 10” round combination 

transition (VP562, sold separately) is 17 1/2”  tall.

Two Dual Blowers (Two B200s): 

Two 8” rounds connect directly to the top of the hood. Optional 12” round 

combination transition (VP563, sold separately) is 16 1/2” tall.

SLD Liner

PSLD/PSLB Liner

Summary of Contents for VP526

Page 1: ...nto wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire ...

Page 2: ...00 B200 10 round or equivalent 79 sq in VP562 Optional Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Optional Ducting Requirements NEVER reduce the duct size When combining ducts together the square inch area must reflect the total square inch area of the ducts being combined Do not use flexible or corrugated duct This type of duct will restrict airflow and reduce performance Only use...

Page 3: ...of the liner allowing room for the transition if applicable If back venting the elbow s should be installed so that the non crimped end s are on the inside the collar s of the exhaust outlet s If a transition is used install duct down to the location of the transition outlet plus 1 This will allow the transition to engage 1 inside of duct Consult the connection diagrams next page for further detai...

Page 4: ... for step 10 5 Remove the shipping tape that is securing the E Z Clean shield s inside the hood Remove the E Z Clean shield s by lightly pulling it toward the front of the hood Gently close the back draft damper s from the top side of the hood To remove the blower housing s unsnap the suitcase latches one on each side of the housing The housing s should be pulled forward and gently tipped to clear...

Page 5: ...sly removed from the packaging in Step 4 11 Install the trim piece for the back side of the liner provided in the liner trim kit by hooking one side under the bottom edges of the back countersunk washers Snap the trim piece over the top of the countersunk washers by applying pressure upward and toward the liner wall Repeat this process for the side trim pieces provided in the liner trim kit Note I...

Page 6: ... 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL ...

Reviews: