Thank you for purchasing this quality Ventair ceiling fan. To ensure correct function and safety, please 

read all instructions before using the product and keep all instructions for future reference.   

 

SAFETY PRECAUTIONS 

 

1.  The appliance is not intended for use by persons (including children) with reduced physical, sensory 

or  mental  capabilities,  or  lack  of  experience  and  knowledge,  unless  they  have  been  given 

supervision  or  instruction  concerning  the  use  of  the  appliance  by  a  person  responsible  for  their 

safety.   

2.  Children should be supervised to ensure that they do not play with the appliance. 

3.  An all-pole disconnection switch must be incorporated into the fixed wiring, in accordance with local 

wiring rules. 

 

WARNING: 

FOR  SAFE  USE  OF  THIS  FAN  AN  ALL-POLE  DISCONNECTION 

MUST  BE  INCORPORATED  INTO  THE  FIXED  WIRING  IN 

ACCORDANCE WITH THE WIRING RULES. 

As outlined in clause 7.12.2 of AS/NZS 60335-1 for meeting the 

minimum electrical safety of this standard.   

Please note warranty will be void if installation is without an all-pole 

disconnection incorporated in the fixed wiring in accordance with the 

wiring rules. 

Example: If a fan is connected to a circuit that can be isolated via an 

all-pole safety switch at the switchboard, then this is considered to be 

an all-pole disconnection to the ceiling fan electrical circuit, meeting 

Summary of Contents for ROY1304WH-DC

Page 1: ... picture is for illustration purposes only Styles may vary according to the particular model Ceiling Fan Installation Manual Rev 1 0 ROYALE DC SERIES Models ROY1304WH DC ROY1304WHL DC INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION Read Instructions Carefully For Safe Installation and Fan Operation ...

Page 2: ...re that they do not play with the appliance 3 An all pole disconnection switch must be incorporated into the fixed wiring in accordance with local wiring rules WARNING FOR SAFE USE OF THIS FAN AN ALL POLE DISCONNECTION MUST BE INCORPORATED INTO THE FIXED WIRING IN ACCORDANCE WITH THE WIRING RULES As outlined in clause 7 12 2 of AS NZS 60335 1 for meeting the minimum electrical safety of this stand...

Page 3: ...nted must be capable of supporting a weight of 30kg 6 The fan should be mounted so that the blades are at least 2 1m above the floor 7 Only a licensed electrician should handle the installation 8 The replacement of parts of the safety suspension system device shall be performed by the manufacturer its service agent or suitably qualified persons 9 The fixing means for attachment to the ceiling such...

Page 4: ...and bottom cover x 1 2 Pre assembled fan motor down rod canopy and bottom cover x 1 3 Blades x 4 3 Blades x 4 4 Remote contro x1 4 Remote control x 1 5 Receiver x 1 5 Receiver x 1 6 Balancing kit x 1 6 Balancing kit x 1 7 Blade screws x 9 1 x spare 7 Blade screws x 9 1 x spare 8 Wooden screws for mounting bracket x 2 8 Wooden screws for mounting bracket x 2 9 Light kit x 1 LED driver LED panel Pla...

Page 5: ...joist or structure that is capable of carrying a load of at least 30kg with the two long screws provided Ensure at least 30mm of the screw is threaded into the support NOTE The bracket screws provided are for use with wooden structures only For structures other than wood the appropriate screw type MUST be used Angled Ceiling Installation This fan hanging system supports a maximum 13 degree angled ...

Page 6: ...n operation Fig 4 BLADE INSTALLATION BLADE ATTACHMENT Fig 5 1 Remove the top motor housing from the fan body by turning the top motor housing anticlockwise 2 Insert the blade into the square slot of the motor 3 Secure the blade on the bracket by using 2 blade screws ensuring they are tightened simultaneously 4 Once completed repeat the process on the remaining blades 5 Replace the top motor housin...

Page 7: ...E INCORPORATED IN THE FIXED WIRING IN ACCORDANCE WITH THE WIRING RULES Connect LIVE supply wire to the L of the terminal block on the mounting bracket Connect NEUTRAL supply wire to the N of the terminal block on the mounting bracket Connect EARTH wire to the of the terminal block on the mouthing bracket To be installed by a licensed electrician in accord with AS NZS 3000 ...

Page 8: ...inside the canopy and that the wires are not damaged during this step Secure the canopy to the hanger bracket using the screws provided How to replace the LED driver For models with light kit NOTE Always turn OFF the power at the mains switch before attempting to replace the LED driver Loosen the screw A to lift the top housing B Replace the LED driver by unplugging the connectors C D Reposition t...

Page 9: ... activated Press and change the speed of the ceiling fan by the remote to check the operation and successful paring Note Use same pairing process if replacing existing handset with new handset EG in case of fault or damage to original handset 1 F R button Press F R button to set up ceiling fan to operate in forward or reverse 2 FAN ON OFF button Press to turn ON or turn OFF the ceiling fan 3 Timer...

Page 10: ...ction after installation Loss of control Remote cannot communicate with the receiver Solution Switch off the main power to ceiling fan Press and hold the button on the remote for 5 seconds within 30 seconds of re instating the power isolation switch ON The fan will have bee bee sound to indicate the paring process is activated Turn ON and change the speed of the ceiling fan by the remote to check ...

Page 11: ...is time Please note that this is not a product fault and as such is not covered under warranty All electric motors are audible to some extent CARE AND CLEANING NOTE Always turn OFF the power at the mains switch before performing any maintenance or attempting to clean your fan Every 6 months periodic cleaning of your ceiling fan is the only maintenance required Use a soft brush or lint free cloth t...

Page 12: ...tenance can reduce or prevent this problem Night Noises This is the biggest cause of service calls which are outside the manufacturer s warranty If a fan has a fault then it would be noticeable at ALL TIMES Obviously when everything is quiet at night you will be more inclined to hear small noises which may not be noticeable at other times Even slight signals super imposed in your electricity suppl...