11126 McCormick Road, Hunt Valley, MD 21031 | 800-851-4965 | sales@ventev.com | ventevinfra.com |
Rev. 022822
22
3.9.4
Console Port
The console port is a standard Cisco RS232 configuration port on an RJ45 socket. The port for Cisco access points is 9600
Baud, 8 Data Bits, No Parity, 1 Stop Bit. Other vendors may use different formats.
TABLE 5: Cisco Console Port Wiring
PIN
FUNCTION
PIN
FUNCTION
1
RTS
5
GND
2
DTR
6
RXD
3
TXD
7
DSR
4
GND
8
CTS
3.10
Intrinsically Safe RF Outputs
Warning!
The Hazardous Environment Enclosure intrinsically Safe RF output ports are located in
the positions shown in Section 3.3. Only antennas in accordance with Section 3.11 may
be connected to these ports. Refer to Section 3.12 for antenna installation requirements.
Warning!
Although antennas connected to the intrinsically Safe RF outputs of the Hazardous
Environment Enclosure may be installed in a hazardous areas requiring Category 1
equipment, the Hazardous Environment Enclosure flameproof enclosure must NOT be
installed in these environments.
Warning!
Do not exceed the RF Threshold Power for the equipment group in which the Hazardous
Environment Enclosure and its antennas are to be installed; it must be controlled in
accordance with IEC 60079-0, and must not exceed the following levels:
IIC
–
2W (+33dBm) IIB
–
3.5W
(+35.4dBm) IIA
–
6W (+37.7dBm) III
–
6W (+37.7dBm)
The RF outputs of the Hazardous Environment Enclosure are approved as:
Ex ia IIC Ga Ex
ia IIIC Da Um =
253Vr.m.s