25
3.13
Prevention of Electrostatic Charging
The Hazardous Environment Enclosure can build up electrostatic charge on its surfaces, so the following steps are to
be followed to reduce static charge build up:
Static charge build up should be reduced by:
•
Connecting the enclosure to a suitable earth point.
•
Cleaning off surface dust using a damp cloth.
•
Not installing into areas where high airflow can occur.
3.14
Additional Labels & Non-Metallic Materials
Additional labels may be fitted to the enclosure. Label material may be stainless steel or any other non-metallic
material. To prevent an electrostatic risk, non-metallic materials must only be cleaned with a damp cloth.
If non-metallic materials are used, consideration should be given to the following:
•
Control of environmental humidity to minimize the generation of static electricity.
•
Protection from direct airflow causing a charge transfer.
•
Touch with an insulation object.
•
Means to continuously drain off electrostatic charges.