Warning!
The Hazardous Environment flameproof enclosure must only be fitted with suitably
approved cable entry devices. See Section 3.3 for details.
Warning!
Do not exceed the RF Threshold Power for the equipment group in which the Hazardous
Environment Enclosure and its antennas are to be installed; it must be controlled in
accordance with IEC 60079- 0, and must not exceed the following levels:
IIC
–
2W (+33dBm) IIB
–
3.5W
(+35.4dBm) IIA
–
6W (+37.7dBm) III
–
6W (+37.7dBm)
See Section 3.10.1 for an example of how to calculate the RF Threshold Power.
Warning!
The Hazardous Environment Enclosure must not be modified in any way.
Warning!
There are no user-serviceable parts below the top plate of the Hazardous Environment
Enclosure. See Section 3.5 for details. Always refer service enquiries to Ventev.
Warning!
Hazardous voltages are present within the Hazardous Environment Enclosure.
Warning!
Hot surfaces may be present within the Hazardous Environment Enclosure. Observe the
warning labels fitted.
Warning!
Optical radiation hazards may be present within the Hazardous Environment Enclosure.
Observe the warning labels fitted.
Warning!
The Hazardous Environment Enclosure may weigh up to 70Kg. Exercise care when
handling and mounting.