background image

17. Verify that the circles under the flags column in the "BREADCRUMB TABLE" tab are green. A green circle 

means the radios are connected. A blue circle means the radios are not connected.  If the blue LED is 

nonoperational, then the antennas are not operational.

18. Link on the "TOPOLOGY VIEW" tab.
19. From the main menu, select VIEW  -> TOPOLOGY LAYOUT -> DEFAULT LAYOUT.
20. Click on the light blue and green links between the radios in the "TOPOLOGY VIEW" tab to verify all the 

antennas are connected. There will be data listed in all fields in the pop-up window (shown below).  The 

antenna with no data listed is not operational. 

www.ventev.com/infra

sales@ventev.com

800.851.4965

16.  Identify the radio at the node you are troubleshooting via the radio’s serial number located on the label by 

the ZEROIZE  button.  If you don’t see the breadcrumb radio with that serial number on the network in the 

"BREADCRUMB  TABLE" tab, then the radio is not operational.

21. Click on the radio with serial number under test in the "TOPOLOGY VIEW" tab.
22. Click on the "PEERS" tab.
23. Verify all the antennas have good cost values. The cost should be under 1000. If the cost is over 1000, 

then there is interference in the area where the enclosure system is deployed which is not allowing it 

to connect. The enclosure system will need to be relocated.

Troubleshooting Guide for the

KM3-ES-2450-AC NEMA 4X Enclosure System for Rajant

Screen shot of Steps #19 and #20