background image

www.ventev.com/infra

sales@ventev.com

800.851.4965

1. Identify the radio you are troubleshooting at the node via the radio’s serial number located on the label by 

the ZEROIZE button. If you don’t see the breadcrumb radio with that serial number on the network in the 

"BREADCRUMB TABLE" tab, then the radio is not operational.

16.  Verify that the circles under the flags column in the "BREADCRUMB TABLE" tab are green. A green circle 

means the radios are connected. A blue circle means the radios are not connected.  If the blue LED is 

nonoperational, then the either the antennas are not operational.

17.  Link on the "TOPOLOGY VIEW" tab.
18. From the main menu, select VIEW -> TOPOLOGY LAYOUT -> DEFAULT LAYOUT
19. Click on the light blue and green links between the radios in the "TOPOLOGY VIEW" tab to verify all the 

antennas are connected.  There will be data listed in all fields in the pop-up window (shown above). The 

antenna with no data listed is not operational.

Screen shot of Steps #18 and #19

20. 

Click on the radio with serial number under test in the "TOPOLOGY VIEW" tab. Click on the "PEERS" tab.

22.  Verify all the antennas have good cost values.  The cost should be under 1000.  If the cost is over 1000, 

then there is interference in the area where the enclosure system is deployed which is not allowing it to 

connect. The enclosure system will need to be relocated.

Troubleshooting Guide for 

Rajant KM3-ES-2450 Enclosure System

Reviews: