HEI150 Wood Insert Fireplace Installation and Operation Manual
27
7 Safety Information
7.1 Summary of Installation Cautions and Warnings
•
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE
APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER
MEDIA (OWNER’S MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB SITES).
•
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH
CHANGES ARE PLANNED, STOVE BUILDER INTERNATIONAL INC. SHOULD BE
CONTACTED IN ADVANCE.
•
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING
BY THE TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI NFPA 211
(USA).
•
CONNECT THIS INSERT ONLY TO A LISTED STAINLESS STEEL CHIMNEY LINER FOR
USE WITH SOLID FUEL.
•
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM.
•
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION
DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
•
THE INSERT AND ITS STAINLESS STEEL CHIMNEY LINER ARE TO BE INSTALLED ONLY
WITHIN A LINED MASONRY CHIMNEY AND MASONRY FIREPLACE CONFORMING TO
BUILDING CODES FOR USE WITH SOLID FUEL. DO NOT REMOVE BRICKS OR MORTAR
FROM THE EXISTING FIREPLACE WHEN INSTALLING THE INSERT.
7.2 Regulations Covering Insert Installation
When installed and operated as described in these instructions, the HEI150 wood insert is
suitable for use in residential installations. The HEI150 wood insert is not intended for
installation in a bedroom.
The construction of the masonry hearth must comply to NFPA 211, CAN/CSA A405 (Design
and Construction of Masonry Chimneys and Fireplaces) or to National Building Code of
Canada.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and
Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the
absence of local code requirements. In the USA, the ANSI NFPA 211 Standard for
Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances and the ANSI NFPA 70
National Electrical Code are to be followed in the absence of local code requirements.
This insert must be installed with a continuous chimney liner of 6” diameter extending from
the insert to the top of the chimney. The chimney liner must conform to the Class 3
requirements of ULC S635, Standard for Lining Systems for Existing Masonry or Factory-
built Chimneys and Vents, or CAN/ULC S640, Standard for Lining Systems for New Masonry
Chimneys or UL 1777, Standard for Chimney Liners.
NOTE: The Insert is not approved for use with a so-called “positive flue connection” to the
clay tile of a masonry chimney.