HEI240 Wood Insert Fireplace Installation and Operation Manual
43
Appendix 2: Fresh Air Intake Kit Installation
Note
: Only remove the knock-out that will be connected to the fresh air inlet.
To install a fresh air intake kit to the insert, the purchase of accessory AC01298 is
required, sold separatly.
Using pliers, remove the rectangular knock-out plate
(A)
located on the left or right side
of the convection air jacket. Choose the side that is best for your installation. Then, install
the fresh air kit adapter
(B)
using 4 screws
(C)
. Secure the flexible pipe
(E)
(The pipe must
be HVAC type, insulated, and must comply with ULC S110 and/or UL 181, Class 0 or
Class 1.) to the adapter
(B)
using one of the adjustable pipe clamps
(D)
. Secure the other
end of the pipe to the outside wall termination
(F)
using the second adjustable pipe clamp
(D)
. The outside wall termination
(F)
must be installed outside of the building.