Page 31
Installation and Operation Manual - HES 240
ENGLISH
8.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
14 ½" (368 mm)
11" (279 mm)
A
9" (229 mm)
9" (229 mm)
B
19" (483 mm)
18" (457 mm)
B
19" (483 mm)
19" (483 mm)
C
10" (254 mm)
10" (254 mm)
C
7" (178 mm)
7" (178 mm)
L
77" (196 cm)
77" (196 cm)
L
77" (196 cm)
77" (196 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
12
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
12
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
14 ½" (368 mm)
D
12 ¼" (311 mm)
12 ¼" (311 mm)
E
28 ½" (724 mm)
27 ½" (699 mm)
E
28 ¼" (718 mm)
28 ¼" (718 mm)
F
19 ¾" (502 mm)
19 ¾" (502 mm)
F
16 ½" (419 mm)
16 ½" (419 mm)
8.1.3 With Heat Shield AC02710 and Lowered Ceiling13
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES
12
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
5" (127 mm)
5" (127 mm)
D
8 ¼" (210 mm)
8 ¼" (210 mm)
B
6" (152 mm)
6" (152 mm)
E
15 ¼" (387 mm)
15 ¼" (387 mm)
C
5" (127 mm)
5" (127 mm)
F
14 ½" (368 mm)
14 ½" (368 mm)
L
80" (203 cm)
80" (203 cm)
12
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
13
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe connector
to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.