To complete the installation, make a hole of 1/4" to 1/2" (6 mm à 13 mm) bigger than the insulate pipe
diameter in the outside wall of the house at the chosen location. From outside, place the outside air inlet
cap in the hole (open side down) and fasten the register to the wall, with screws as shown bellow. Place the
insulated pipe over the register tube and over the fireplace outside air connector. At each end, carefully pull
back the insulation and plastic cover, exposing the flexible pipe. Attach the flexible pipe using pipe clamps.
For a better seal, you may also use aluminum tape. Wrap the tape around the joint between the flexible
pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Fix the plastic in
place using aluminum tape.