56
ME300 - Installation and Operation Manual
For AC01375 installation:
1.
Secure the 6 steel brackets (D) with 6 screws provided (E) on top of the fireplace (3 for each
ducting). Insert the ducting (G) (not provided) into each opening and secure it in place using the
steel brackets (D) installed previously with 6 other self-tapping screws provided (F).
2.
Secure the ducting (G) to the 90° elbows (C) with self-tapping screws (3 per elbow). Insert the hot air
outlets (B) in the elbow (C). Set hot air outlets frames behind the non-combustible materiel and
secure to the wall with screws. Secure hot air outlets (B) to the elbows (C) with 3 self-tapping screws
each. Secure the hot air outlets grilles (A) to the frames with screws.
3.
Maintain at least a 2" (50 mm) clearance between the ducts and the firestop; the required hole size
for the hot air grilles (outlet) is 8¼" × 8¼" (210 mm × 210 mm).
4.
The maximum number of elbows in a run of duct is two.
5.
Maintain at least 10" (254 mm) clearance from the outlet grille framing to a combustible ceiling, side
wall or mantel.
6.
When passing through a combustible wall or floor, a firestop must be installed at the wall or floor
penetration. The hole size must be in accordance with the duct manufacturer’s instructions.