Operation mode 

 — the fan operates without any activation signal from the switch, humidity or motion sensor.

Operation mode 

 — the fan operates with activation signal from the switch, humidity or motion sensor.

 —  back to the upper setup menu level.

Once the switch is turned on or the humidity or motion sensor is activated, the fan switches from the mode 

 to the mode 

. After a signal 

is no more received from the sensor in case of the indoor humidity normalization, or no more motion is detected in case of the fan shutdown, 
the fan keeps  running for a set turn-off delay time and then switches from the mode 

 to the mode 

.

SETUP OF THE OPERATION MODES 

 AND 

 

The 

 and 

 modes can take the following values for the fan with an AC motor:

 — the fan is turned off.
 — the fan operates at reduced performance.
— the fan operates at maximum performance.

Example 1

 = 

 = 

 — with these activated settings the fan is constantly turned off. Once the switch is turned on or a sensor is 

activated, the fan starts to run at reduced performance.

Example 2

 = 

 = 

 — with these activated settings the fan runs at reduced performance. Once the switch is turned on or a sensor 

is activated, the fan starts to run with the maximum capacity. This setting is factory set and is the default setting.

MAINTENANCE

The fan maintenance includes regular cleaning of the surfaces of dust and dirt. Replace the filter as required, but at least every 6 months.
The impeller cleaning is shown below. Clean the impeller blades thoroughly every 6 months. 

DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE 

ANY MAINTENANCE OPERATIONS!

Summary of Contents for CBF 110

Page 1: ...CBF 110 130 CBF 110 130 T TH TP CBF 110 130 LIGHT CBF 110 130 LIGHT T TH TP Centrifugal ceiling fan USER S MANUAL...

Page 2: ...or to installing and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must...

Page 3: ...ic parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly fla...

Page 4: ...s THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY P...

Page 5: ...ing bracket 4 pcs Fastening kit 1 pc User s manual 1 pc Packing box 1 pc Ceileo 130 Light TP Additional options T timer TH humidity sensor and timer TP motion sensor and timer Basic options _ no integ...

Page 6: ...8 3 15 16 1 3 4 13 10 3 16 10 1 4 15 9 16 7 3 8 11 16 Ceileo 110 130 Light Ceileo 110 130 Light T TH TP 5 7 8 3 7 8 3 15 16 1 3 4 13 10 3 16 10 1 4 15 9 16 7 3 8 2 7 6 8 3 16 4 13 16 The unit is desi...

Page 7: ...73 SFP W l s 0 55 0 50 0 49 0 54 Weight kg 5 3 6 4 5 3 6 4 lbs 11 7 14 1 11 7 14 1 IP X4 SEC class D C For fans with light only TECHNICAL DATA CBF 110 130 DC T TH TP CBF 110 130 DC LIGHT T TH TP DESI...

Page 8: ...f the fan is turned on or goes to high speed after countdown of a set turn on delay time adjustable from 0 to 3 minutes After the fan is turned off it keeps running for a set turn off delay time adjus...

Page 9: ...E THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and loc...

Page 10: ...dels with a humidity sensor remove the protective cap from the grille prior to its installation Route the contact socket of the sensor TH or TP via the opening in the grille and connect the sensor soc...

Page 11: ...of the ceiling joists Installation between the ceiling joists Fixation between the ceiling joists using the mounting brackets Additional fastening holes in the fan casing may be used for mounting pur...

Page 12: ...ERMINAL BOX FOR WIRING THE FAN L2 L1 N L N LT N L N L 1 2 3 4 5 6 7 LIGHT contact socket is available only for the models with LED light FAN 1 QF QF 120 V 60 Hz 120 V 60 Hz Remove the decorative grill...

Page 13: ...to navigate in the Setup menu Press to select a current entry in the Setup menu After that the indicator displays the selected parameter value e g turn off delay timer setting Use or to change the va...

Page 14: ...take the following values for the fan with an AC motor the fan is turned off the fan operates at reduced performance the fan operates at maximum performance Example 1 with these activated settings th...

Page 15: ...SIBLE REASONS TROUBLESHOOTING The fan does not get started No power supply Check the electric connections and the operation status of the circuit breaker Motor jam Turn the fan off Troubleshoot cloggi...

Page 16: ...machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the origina...

Page 17: ...recommended installation instructions Labor to remove and replace products is not covered The duration of any implied warranty is limited to the time period specified for the express warranty Some st...

Page 18: ...equirements stated in the present user s manual Installation Company Stamp Seller Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in ac...

Page 19: ...19 vents us com...

Page 20: ...VUSA166 1EN 01...

Reviews: