Install the ventilation hood MICRA 60 on the outer side of the building to prevent ingress of foreign objects into the air ducts, fig. 7. 

Fig. 5

7. Unit installation sequence:
- Open the front panel and remove the heat exchanger.
- Connect the unit spigots to the plastic air ducts.
- Fix the unit to wall with the screws 5,0x50 from the delivery set 
by inserting those to the Ø 8 mm (5/16'') holes.
-Install the heat exchanger and close the front panel.
-Install the NB MICRA 60 outer ventilation hood outer of the 
building to prevent ingress of large foreign objects into the air 
ducts, fig. 5. 

Attention! The round plastic air ducts and the outer ventilation hood are not included intro thr delivery set and are available on separate order. You may use other ventilation 

grilles and hoods of the matching size.

SPEED SWITCH MOUNTING

MAKE SURE  THAT SPEED SWITCH IS NOT DAMAGED. DO NOT OPERATE A DAMAGED SPEED SWITCH! DO NOT INSTALL THE SPEED SWITCH ON AN UNEVEN SURFACE! DO NOT APPLY 

EXCESSIVE FORCES WHILE TIGHTENING THE SCREWS TO AVOID THE SPEED SWITCH CASING DEFORMATION.

- Route all the required cables and wires to the speed switch installation place.
- Insert the junction box from the delivery set inside the wall.