The shutters are closed
The shutters are open
TwinFresh Expert RА1 LOUVER SHUTTERS OPERATION PRINCIPLE
RA1 version is equipped with automatic shutters. During the ventilator operation the automatic shutters open and let the air flow freely
through the ventilator. The automatic shutters are closed for 2 minutes at the ventilator shut down.
WARNING!
In case of supplying power to the ventilator when the frontal part of the indoor unit is removed, no power is supplied to the
actuator and its rod is not lifted to avoid damage. After installing the front part of the indoor unit into place, the louver actuator will start
operating normally.
VENTILATOR OPERATION MODES
TwinFresh Expert RA/M1
TwinFresh Expert Duo RA1
Ventilation:
the ventilator runs either in extract or supply mode
at a set speed.
In this mode, when two ventilators are installed, one of them
supplies and the other one extracts the air.
Boost:
the ventilator goes to the maximum speed without
changing the operation mode.
Regeneration:
the ventilator runs in two cycles, 70 seconds each,
with heat and humidity regeneration.
•
Cycle I
. Warm stale air is extracted from the room and flows
through the ceramic regenerator, which gradually absorbs
heat and humidity. In 70 seconds, as the ceramic regenerator
gets warmed, the ventilator is switched to supply mode.
•
Cycle II
. Fresh intake air from outside flows through the ceramic
regenerator, absorbs accumulated moisture and is heated
up to the room temperature. In 70 seconds, as the ceramic
regenerator gets cooled down, the ventilator is switched to air
extract mode and the cycle is renewed. If two ventilators are
installed, they operate with opposite rotation directions in this
mode. While one ventilator supplies air, the other one extracts
it.
Ventilation:
one of the ventilator fans operates in the air extract
mode and the other one operates in the air supply mode at a set
speed. The fans do not change their rotation direction.
Boost:
if the sensor is actuated, the ventilator follows one of two
functioning algorithms set via the DIP switch during the ventilator
setup. For details, see page 14. The DIP switch is set to OFF: the
ventilator runs in the extract mode at the third speed (both fans
run in the extract mode). The DIP switch is set to ON: the ventilator
switches to maximum speed without changing the operation
mode.
Regeneration:
one of the ventilator fans operates in the air
extract mode and the other one operates in the air supply mode.
The fans change their rotation direction every 70 seconds.