TwinFresh Expert (Duo) RW1
www.ventilation-system.com
VENTILATOR CONTROL WITH THE BUTTONS ON THE INDOOR UNIT
The speed selection sequence is follows:
I-II-III-Standby
All the units integrated in a single network operate according to the speed settings of the Master unit.
I:
permanent indicator glowing indicates operation of the unit at Speed I.
The indicator blinks when the first speed timer is activated.
I and II:
permanent glowing of the indicators I and II indicates operation of the unit at Speed II.
I, II and III:
permanent glowing of the indicators I, II and III indicates operation of the ventilator at Speed III.
Blinking of the indicators I, II and III indicates activation of the timer for Party mode or the turn-off delay timer triggered by any connected
external sensors or the integrated humidity sensor.
Alternate blinking of the indicators I, II and III indicates that the ventilator runs at the speed set with the mobile application using the slider
selector for manual speed setting.
Regeneration mode.
TwinFresh Expert RW1
The rotation direction of both fans changes to opposite every 70 seconds. Heat recovery is performed in this mode. When several ventilators are
operating on the network, it is necessary to configure a different direction of rotation of the fans using the application on a PC.
TwinFresh Expert Duo RW1
The rotation direction of both fans changes to opposite every 70 seconds. Heat recovery is performed in this mode.
Ventilation mode.
TwinFresh Expert RW1
The ventilator operates in permanent air supply or air extraction mode at set speed.
The ventilation unit operates in the air supply or extraction mode with a set speed. The fan rotation direction depends on PC setting (air
extraction mode by default).
TwinFresh Expert Duo RW1
One fan operates in the air extraction mode and the other fan operates in the air supply mode at set speed. The fans do not change their
rotation direction.
No glowing of the indicators «Regeneration» and «Ventilation» indicates forced operation of the ventilation unit in the air supply mode.
This mode may be activated only via the mobile application.
Filter
Contamination indicator of filters.
90 days (continuous operation) after installation of the cartridge the Filter contamination indicator starts glowing.
In this case, clean or replace the filters (see the «Technical maintenance» section).
Reset the timer after filter replacement:
• ventilators operating in Master mode using a DIP switch, an application on a mobile device or using a PC;
• ventilators operating in Slave mode using a DIP switch or PC.
Alarm
Alarm indicator for emergency shutdown of the unit. Permanent glowing of the Alarm indicator of the Master unit indicates an alarm in the
network of the connected ventilation units. Its blinking indicates shutdown of a specific ventilation unit in the network.
In case of an emergency shutdown of a TwinFresh Expert RW1 unit in the network the defective ventilation unit is marked with the blinking
Alarm indicator. All the connected TwinFresh Expert RW1 ventilation units are also stopped. All the connected TwinFresh Expert Duo RW1
ventilation units continue operating. In case of an emergency shutdown of a TwinFresh Expert Duo RW1 unit in the network the defective
ventilation unit is marked with the blinking Alarm indicator. The defective ventilation unit shuts down and the other connected ventilation
units continue their operation.
Master
Master unit indicator
Permanent glowing of the indicator shows the leading unit in the network (Master unit).
Indicator blinking indicates the driven unit (Slave unit) and no connection to the Master unit.
No glowing of the lamp indicator means that this ventilation unit is a Slave ventilation unit and it is connected to a Master unit.
Synchronous blinking of all the lamp indicators on the casing of the ventilation unit means active setup mode performed by a PC.
In this case the fan shuts down.