SAFETY REQUIREMENTS

All operations described in this manual must be performed by qualified personnel only, properly 
trained and qualified to install, make electrical connections and maintain ventilation units.
Do not attempt to install the product, connect it to the mains, or perform maintenance yourself.
This is unsafe and impossible without special knowledge.
Disconnect the power supply prior to any operations with the unit.
All user’s manual requirements as well as the provisions of all the applicable local and national 
construction, electrical, and technical norms and standards must be observed when installing and 
operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are allowed 

for installation. The present user’s manual should be carefully read before beginning works.

Check the unit for any visible damage of the impeller, the casing, and the grille before starting 
installation. The casing internals must be free of any foreign objects that can damage the impeller 
blades. 
While mounting the unit, avoid compression of the casing! Deformation of the casing may result in 
motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous 
materials.
Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, 
insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this user’s manual was correct at the time of the document’s preparation. 
The Company reserves the right to modify the technical characteristics, design, or configuration of 
its products at any time in order to incorporate the latest technological developments.
Never touch the unit with wet or damp hands.
Never touch the unit when barefoot.
BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES, READ THE RELEVANT USER MANUALS.

The installation site of the fan must have protective elements that prevent foreign objects from 
entering the fan.
When starting, setting up and operating the fan, the exhaust and supply spigots must be protected 
to prevent injury from the rotating parts of the fan.

3

vents-us.com

Summary of Contents for VKP 100

Page 1: ...USER S MANUAL Inline centrifugal fan VKP VKPF...

Page 2: ...nty card 15 This user s manual is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle d...

Page 3: ...While mounting the unit avoid compression of the casing Deformation of the casing may result in motor jam and excessive noise Misuse of the unit and any unauthorised modifications are not allowed Do...

Page 4: ...g rules for design of electrical units and has a contact separation in all poles that allows for full disconnection under overvoltage category III conditions If the supply cord is damaged it must be r...

Page 5: ...thhighrequirements to the noise level and with limited space for mounting The unit is rated for continuous operation The unit is a component part and is not designed for stand alone operation Transpor...

Page 6: ...0 27 3 7 104 98 94 89 84 77 69 61 52 43 33 1 2 120 60 VKP 125 5 66 0 54 4 2 220 214 208 202 196 190 184 178 172 160 150 2 4 120 60 VKP 125 125x2 5 5 74 0 61 4 2 244 234 223 213 204 194 183 170 160 150...

Page 7: ...urved blades fixed to a flange The terminal box with an operating capacitor and a terminal box inside is attached to the casing end face The flange with the turbine and the fixing bracket with mountin...

Page 8: ...qual to 1 air duct diameter on intake side and to 3 air duct diameters on outlet side No filters or any other similar devices are allowed to be installed in these sections CAUTION If necessary close t...

Page 9: ...insulated flexible duct between any exhaust grill and fan for low noise level Flexible duct should be connected to the fan with hose clamps VENTS C series is recommended aluminum foil tape or both Al...

Page 10: ...it breaker installation place must provide quick access for emergency shutdown of the unit The trip current of the automatic circuit breaker QF must exceed the maximum current consumption of the unit...

Page 11: ...y using a soft wet cloth and mild detergent Pic 21 24 Do not allow liquids to come in contact with the electric motor Wipe surfaces dry after cleaning Perform all the above operations in the reverse o...

Page 12: ...off the fan Troubleshoot the motor jamming Restart the fan Circuit breaker tripping during the fan start Excessive electric current consumption caused by a short circuit Turn off the fan Contact the...

Page 13: ...and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mod...

Page 14: ...ended installation instructions Labor to remove and replace products is not covered The duration of any implied warranty is limited to the time period specified for the express warranty Some states do...

Page 15: ..._____________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Instal...

Page 16: ...VUSA17EN 06...