background image

2

DuoVent 150/200/250/315/355/400 EC

www.ventilation-system.com

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the 
DuoVent 150/200/250/315/355/400 EC unit and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

Safety requirements ..................................................................................................................................................................... 2
Purpose ................................................................................................................................................................................................ 4
Delivery set ........................................................................................................................................................................................ 4
Designation key .............................................................................................................................................................................. 4
Technical data .................................................................................................................................................................................. 5
Design and operating principle ........................................................................................................................................... 7
Mounting and set-up .................................................................................................................................................................. 8
Connection to power mains .................................................................................................................................................. 9
Technical maintenance .............................................................................................................................................................. 11
Troubleshooting ............................................................................................................................................................................. 11
Storage and transportation regulations .......................................................................................................................... 12
Manufacturer’s warranty ........................................................................................................................................................... 13
Certificate of acceptance .......................................................................................................................................................... 15
Seller information .......................................................................................................................................................................... 15
Installation certificate .................................................................................................................................................................. 15
Warranty card ................................................................................................................................................................................... 15

All operations described in this manual must be performed by qualified personnel only, properly 
trained and qualified to install, make electrical connections and maintain ventilation units.
Do not attempt to install the product, connect it to the mains, or perform maintenance yourself.
This is unsafe and impossible without special knowledge.
Disconnect the power supply prior to any operations with the unit.
All user’s manual requirements as well as the provisions of all the applicable local and national 
construction, electrical, and technical norms and standards must be observed when installing 
and operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are 

allowed for installation. The present user’s manual should be carefully read before 

beginning works.

Check the unit for any visible damage of the impeller, the casing, and the grille before starting 
installation. The casing internals must be free of any foreign objects that can damage the 
impeller blades. 
While mounting the unit, avoid compression of the casing! Deformation of the casing may result 
in motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous 
materials.

SAFETY REQUIREMENTS

CONTENTS

Summary of Contents for DuoVent 150 EC

Page 1: ...DuoVent 150 EC DuoVent 200 EC DuoVent 250 EC DuoVent 315 EC DuoVent 355 EC DuoVent 400 EC Duct redundancy fan unit in a sound insulated casing USER S MANUAL ...

Page 2: ...nd maintain ventilation units Do not attempt to install the product connect it to the mains or perform maintenance yourself This is unsafe and impossible without special knowledge Disconnect the power supply prior to any operations with the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standard...

Page 3: ...ced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Cleaning and user maintenance shall not be made by children without supervision Children shall not play with the appliance Connection to the mains must be made through a disconnecting dev...

Page 4: ...ed space for mounting The fan unit is a component part and cannot be used for stand alone operation It is rated for continuous operation Transported air must not contain any flammable or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathoge...

Page 5: ... models may be slightly different from those described in this manual TECHNICAL DATA Weight and overall and connecting dimensions of the fan unit mm Model L L1 L2 L3 H A A1 A2 ØD Weight kg DuoVent 150 EC 975 850 748 321 621 593 540 149 28 DuoVent 200 EC 975 850 748 375 791 763 710 199 39 DuoVent 250 EC 1102 979 877 417 801 773 720 249 53 DuoVent 315 EC 1293 1170 1068 534 520 1092 1065 1010 314 97 ...

Page 6: ...6 DuoVent 150 200 250 315 355 400 EC www ventilation system com Technical specifications of the particular model are indicated on the unit casing ...

Page 7: ...l automatics the fans can be switched on alternately at different time intervals This ensures uninterrupted ventilation in case of failure of one fan the second one automatically switches on Switching modes is carried out using a controller which is not included in the basic delivery set and must be ordered separately In order to prevent air backflow through a non functioning fan a swivel damper i...

Page 8: ... section Fasteners for unit mounting should be selected by the service technician The safety cables on the removable service panels can be moved to the opposite side of the casing for the convenience of service work depending on the installation location of the fan unit MOUNTING AND SET UP WHILE INSTALLING THE UNIT ENSURE CONVENIENT ACCESS FOR SUBSEQUENT MAINTENANCE AND REPAIR BEFORE MOUNTING MAKE...

Page 9: ...ion method The external power input must be equipped with an automatic circuit breaker built into the stationary wiring to open the circuit in the event of overload or short circuit The position of the external circuit breaker must ensure free access for quick unit power off The trip current of the automatic circuit breaker must exceed the maximum current consumption of the unit refer to the Techn...

Page 10: ...DuoVent 250 EC DuoVent 315 EC DuoVent 355 EC DuoVent 400 EC GND 0 10V N L TACH 10V GND 0 10V TACH 10V GND 0 10V TACH 10V GND 0 10V TACH 10V N L 10V CTR X2 TACH GND 10V CTR TACH GND N L 2 X1 QF N L Red White Yellow Blue External control device 1 220 240 V Blue Brown 10V CTR X2 TACH GND 10V CTR TACH GND N L N L X1 QF Red White Yellow Blue External control device 1 220 240 V Blue Brown Yellow green ...

Page 11: ...ECTION AVOID LIQUID SPILLS ON THE MOTOR DO NOT USE AGGRESSIVE SOLVENTS AND SHARP OBJECTS FOR CLEANING PRIOR TO COMMENCING ANY TECHNICAL MAINTENANCE PUT UP A PROHIBITORY SIGN ON THE FAN STARTING PANEL DO NOT SWITCH ON MEN AT WORK TECHNICAL MAINTENANCE TROUBLESHOOTING Problem Possible reasons Troubleshooting The fan s doesn t don t start No power supply Make sure the power supply line is connected c...

Page 12: ...Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blo...

Page 13: ...tling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model must comply with the one stated in the user s manual Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire...

Page 14: ...14 DuoVent 150 200 250 315 355 400 EC www ventilation system com ...

Page 15: ...ATE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical codes and sta...

Page 16: ...V256EN 03 ...

Reviews: