background image

8

TRANSPORTATION AND STORAGE RULES 

Transportation with any transportation vehicle in the manufacturer's original package.  
Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the temperature 
from  +5 °C up to + 40  °C and relative humidity below 80

 

%.  

The storage environment must not contain dust, acid or alkali vapours that may cause corrosion of the product parts.  

MANUFACTURER'S WARRANTY  

The fan is manufactured at the factory of  Ventilation systems  PrJSC (hereinafter referred to as the manufacturer). 
We hereby declare that the product complies with the protection requirements of Electromagnetic Council 
Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and CE-marking Directive 93/68/EEC on the approximation 
of the laws of the Member States relating to electromagnetic compatibility.
This certificate is issued following the test on the samples of the product referred to above. 
The manufacturer sets forth the warranty period of the fan as 60 months following the sale date via retail network subject 
to the customer's ensuring compliance with the rules of transportation, storage, mounting and operation. 
In case of any malfunction of the fan through the manufacturer's fault within the warranty period  the customer is entitled 
to free elimination of the defects by means of warranty repair.  
The warranty repair means performing works specific to elimination of faults in the fan operation to ensure its intended 
use by the user within the warranty period.  
The defects are eliminated by means of replacement or repair of the complete fan or a faulty part thereof.  

The warranty repair does not include:  

Routine maintenance; 
Fan installation / dismantling;  
Fan setup.  
To benefit from warranty repair the user must provide the fan, the user's manual with stamped sale date and the payment 
document to confirm the purchase.  
The fan model must comply with the one stated in the user's manual.  

Contact the product seller for warranty service, repair or replacement. 

 

The manufacturer's warranty does not apply to the following cases:  

 

user's failure to provide the fan in the entire delivery package as stated in the user's manual, including missing component 

  

parts previously dismounted by the user; 

 

mismatch of the fan model and make with the respective details stated on the fan packing and in the user's manual; 

 

user's failure to ensure timely technical maintenance of the fan; 

 

external damage to the casing (excluding external modifications of the fan as required for its installation) and the internal 

  

components of the fan; 

 

alteration of the fan design or engineering changes of the fan; 

  

EN

Summary of Contents for Quiet Style 12

Page 1: ...www ventilation system com EN AXIAL FANS User s manual model VENTS Quiet S VENTS Quiet Style ...

Page 2: ...ns must comply with the acting local electrical norms and standards The fixed electrical wiring must be equipped with an automatic circuit breaker The fan must be connected to power mains through an automatic circuit breaker QF integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm Check the fan for any visible damages of the impeller and ...

Page 3: ...r combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials 3 WARNING Follow the user s manual requireme...

Page 4: ...do not put objects on it The timer circuit is under mains voltage Disconnect the fan from power supply prior to any adjustment operations The fan delivery set includes a specially designed plastic screwdriver for adjustment of the fan parameters Use exclusively the delivered plastic screwdriver to adjust the fan settings 4 WARNING Follow the user s manual requirements to ensure durable and trouble...

Page 5: ...ion or instruction regarding a safe use of the product and understand the risks involved Do not allow children play with the product Fan cleaning and maintenance must only be performed by children under adult supervision Recycle at the end of the service life Do not dispose the product with unsorted municipal trash 5 WARNING Follow the user s manual requirements to ensure durable and trouble free ...

Page 6: ... on as the indoor humidity exceeds set level adjustable from 60 up to 90 As the indoor humidity level drops down below the set point the fan keeps operating for a set turn off delay time period adjustable from 2 to 30 minutes The fan may be manually turned on with a light switch After the switch is turned off the fan keeps operating for a set turn off delay time period adjustable from 2 to 30 minu...

Page 7: ...on shaft or a round air duct of a matching diameter Attention In case of vertical mounting the fan must be protected against ingress of rainfalls and condensate inside the fan Fan installation with direct air discharge upwards is not allowed Fig 3 The fan mounting sequence is shown in Fig 5 13 The fan wiring diagrams are shown in Fig 14 17 Setting of the turn off and turn on delay time as well as ...

Page 8: ...facturer s fault within the warranty period the customer is entitled to free elimination of the defects by means of warranty repair The warranty repair means performing works specific to elimination of faults in the fan operation to ensure its intended use by the user within the warranty period The defects are eliminated by means of replacement or repair of the complete fan or a faulty part thereo...

Page 9: ...hed regulations specific to the fan transportation user s violation of the fan storage regulations wrongful acts against the fan committed by third persons fan breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockade etc missing seals if provided by the user s manual failure to submit the user s manual with the sale date stamp failure to submit...

Page 10: ...2 1 3 4 10 openings for latches ...

Page 11: ...6 11 11 8 5 12 9 6 13 10 7 QF L N ...

Page 12: ...00 Quiet Style V 100 Quiet S VT 100 Quiet Style VT 100 Quiet S T T1 100 Quiet Style T T1 Switch is OFF during countdown of turn on delay timer yes no Activation of turn on delay timer 0 2 minutes Switch is ON Switch is OFF Fan runs Fan does not run Switch is ON Fan does not run Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Fan runs Switch is OFF ...

Page 13: ...urn off delay timer 2 30 minutes Humidity is below set point Humidity is above set point Fan runs yes no Switch is ON Switch is OFF Humidity is above set point no yes Fan runs Fan runs Humidity is below set point 100 Quiet S TH 100 Quiet Style TH 100 Quiet S VTH 100 Quiet Style VTH ...

Page 14: ...ely adjustable from 0 up to 2 minutes To adjust the fan turn off delay time turn the control knob Toff clockwise to increase and counter clockwise to decrease the turn off delay time respectively adjustable from 2 up to 30 minutes Warning The timer circuit is under mains voltage Disconnect the fan from power supply prior to any adjustment operations The fan delivery set includes a specially design...

Page 15: ...15 23 24 21 22 19 20 QF L N Latches ...

Page 16: ...EN 02 CERTIFICATE OF ACCEPTANCE www ventilation system com The fan is recognized as serviceable V T TH TP 12 Approval mark Manufacturing date Sales date Sold name and stamp of the seller T1 100 Quiet S 100 Quiet Style ...

Reviews: