MANUFACTURER’S WARRANTY

The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby 
declare that the product complies with the provisions of Electromagnetic Council Directive 2014/30/EU, Low Voltage Directive 2014/35/
EU and CE-marking Directive 93/68/EEC. This certificate is issued following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 24 months after the retail sale date provided the user's observance 
of the transportation, storage, installation, and operation regulations. Should any malfunctions occur in the course of the unit operation 
through the Manufacturer's fault during the guaranteed period of operation, the user is entitled to get all the faults eliminated by the 
manufacturer by means of warranty repair at the factory free of charge. The warranty repair includes work specific to elimination of faults 
in the unit operation to ensure its intended use by the user within the guaranteed period of operation. The faults are eliminated by means 
of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include: 

•  routine technical maintenance
•  unit installation/dismantling 
•  unit setup

To benefit from warranty repair, the user must provide the unit, the user's manual with the purchase date stamp, and the payment 
paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty 
service. 

The manufacturer’s warranty does not apply to the following cases:

•  User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with 

missing component parts previously dismounted by the user.

•  Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user's manual.
•  User’s failure to ensure timely technical maintenance of the unit.
•  External damage to the unit casing (excluding external modifications as required for installation) and internal components 

caused by the user.

•  Redesign or engineering changes to the unit.
•  Replacement and use of any assemblies, parts and components not approved by the manufacturer.
•  Unit misuse.
•  Violation of the unit installation regulations by the user.
•  Violation of the unit control regulations by the user.
•  Unit connection to power mains with a voltage different from the one stated in the user's manual.
•  Unit breakdown due to voltage surges in power mains.
•  Discretionary repair of the unit by the user.
•  Unit repair by any persons without the manufacturer’s authorization.
•  Expiration of the unit warranty period.
•  Violation of the unit transportation regulations by the user.
•  Violation of the unit storage regulations by the user.
•  Wrongful actions against the unit committed by third parties.
•  Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
•  Missing seals if provided by the user’s manual.
•  Failure to submit the user’s manual with the unit purchase date stamp.
•  Missing payment paperwork certifying the unit purchase.

FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND 

TROUBLE-FREE OPERATION OF THE UNIT.

USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON 

PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL 

WITH THE PURCHASE DATE STAMP.

Summary of Contents for VCN 100

Page 1: ...VCN 100 VCN 100 K VCN 100 EC VCN 125 VCN 125 K VCN 125 EC VCN 100 VCN 150 K VCN 150 EC VCN 160 VCN 160 K VCN 160 EC VCN 200 VCN 200 K VCN 200 EC VCN 200 EC S Centrifugal fan USER S MANUAL ...

Page 2: ... proper theoretical knowledge and practical training specific to ventilation systems as well as the necessary skills to carry out the work in accordance with labour safety and construction regulations and standards applicable in the respective territory The information provided in the present document is true as at the document preparation Due to the continuous product development the company rese...

Page 3: ...e electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during ...

Page 4: ...perature is up to 50 С Transported air must not contain dust and other solid impurities sticky substances and fibrous materials The fan design is constantly being improved thus some models may be slightly different from those described in this manual THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING T...

Page 5: ...CN 125 EC 125 355 260 140 3 60 VCN 150 VCN 150 EC 150 400 300 140 4 70 VCN 160 VCN 160 EC 160 400 300 140 4 70 VCN 200 VCN 200 EC 200 400 300 140 4 70 VCN 200 EC C 200 400 326 182 5 3 Technical data VCN 100 VCN 100 K VCN 125 VCN 125 K VCN 150 VCN 150 K VCN 160 VCN 160 K VCN 200 VCN 200 K VCN 100 VCN 100 K VCN 125 VCN 125 K VCN 150 VCN 150 K VCN 160 VCN 160 K VCN 200 VCN 200 K Voltage V 1 230 50 Hz...

Page 6: ... protect it against atmospheric influences Set the circuit breaker to OFF Unscrew self tapping screws and remove the cover READ THE USER S MANUAL BEFORE INSTALLING THE UNIT VCN 100 EC VCN 125 EC VCN 150 EC VCN 160 EC VCN 200 EC VCN 200 EC C Unit voltage V 50 60 Hz 1 230 Power W 89 103 92 92 79 102 Current A 0 53 0 83 0 75 0 75 0 67 0 86 Air flow m3 h 313 480 550 585 535 755 RPM min 1 3460 3600 284...

Page 7: ...hase AC 220 230 V 50 60 Hz power mains For electric installations use insulated durable heat resistant wires with the minimum wire cross section 1 mm2 The actual conductor cross section selection must be based on its type the maximum permissible heating insulation length and installation method The external power input must be equipped with an automatic circuit breaker built into the stationary wi...

Page 8: ...cover and tighten the screws Wiring diagram of the fan with an asynchronous motor N L L X QF N PE Wiring diagram of the fan with an EC motor N 10V CTR GND L L X1 QF N PE For the operation of the EC motor it is necessary to install a speed controller not included in the delivery set or to short circuit the contacts 10V and CTR the fan will run at maximum speed ...

Page 9: ...ore the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature range 5 40 С and relative humidity up to 70 Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow th...

Page 10: ...ty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of...

Page 11: ...ian s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical codes and standards The unit operates normally as intended by the manufacturer Signature Seller Seller s Stamp Address Phone Number E mail Purchase Date This is to certify acceptance of the complete unit delivery wi...

Page 12: ...V06EN 04 ...

Reviews: