•  Do not change the power cable length 

at your own discretion. Do not bend 
the power cable. Avoid damaging the 
power cable. Do not put any foreign 
objects on the power cable.

•  Do not lay the power cable of the unit in 

close proximity to heating equipment.

•  Do not use damaged equipment or 

cables when connecting the unit to 
power mains.

•  Do not operate the unit outside the 

temperature range stated in the user’s 
manual. Do not operate the unit in 
aggressive or explosive environments.

•  Do not touch the unit controls with wet 

hands. Do not carry out the installation 
and maintenance operations with wet 
hands.

•  Do not wash the unit with water. Protect 

the electric parts of the unit against 
ingress of water. 

•  Do not allow children to operate the 

unit.

•  Disconnect the unit from power mains 

prior to any technical  maintenance.

•  Do not store any explosive or highly 

flammable substances in close proximity 
to the unit.

•  When the unit generates unusual 

sounds, odour, or emits smoke, 
disconnect it from power supply and 
contact the Seller.

•  Do not open the unit during operation.

•  Do not direct the air flow produced by 

the unit towards open flame or ignition 
sources.

•  Do not block the air duct when the unit 

is switched on.

•  In case of continuous operation of the 

unit, periodically check the security of 
mounting.

•  Do not sit on the unit and avoid placing 

foreign objects on it.

•  Use the unit only for its intended 

purpose.

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE THE UNIT AS UNSORTED MUNICIPAL WASTE.

Summary of Contents for VCN 100

Page 1: ...VCN 100 VCN 100 K VCN 100 EC VCN 125 VCN 125 K VCN 125 EC VCN 100 VCN 150 K VCN 150 EC VCN 160 VCN 160 K VCN 160 EC VCN 200 VCN 200 K VCN 200 EC VCN 200 EC S Centrifugal fan USER S MANUAL ...

Page 2: ... proper theoretical knowledge and practical training specific to ventilation systems as well as the necessary skills to carry out the work in accordance with labour safety and construction regulations and standards applicable in the respective territory The information provided in the present document is true as at the document preparation Due to the continuous product development the company rese...

Page 3: ...e electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during ...

Page 4: ...perature is up to 50 С Transported air must not contain dust and other solid impurities sticky substances and fibrous materials The fan design is constantly being improved thus some models may be slightly different from those described in this manual THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING T...

Page 5: ...CN 125 EC 125 355 260 140 3 60 VCN 150 VCN 150 EC 150 400 300 140 4 70 VCN 160 VCN 160 EC 160 400 300 140 4 70 VCN 200 VCN 200 EC 200 400 300 140 4 70 VCN 200 EC C 200 400 326 182 5 3 Technical data VCN 100 VCN 100 K VCN 125 VCN 125 K VCN 150 VCN 150 K VCN 160 VCN 160 K VCN 200 VCN 200 K VCN 100 VCN 100 K VCN 125 VCN 125 K VCN 150 VCN 150 K VCN 160 VCN 160 K VCN 200 VCN 200 K Voltage V 1 230 50 Hz...

Page 6: ... protect it against atmospheric influences Set the circuit breaker to OFF Unscrew self tapping screws and remove the cover READ THE USER S MANUAL BEFORE INSTALLING THE UNIT VCN 100 EC VCN 125 EC VCN 150 EC VCN 160 EC VCN 200 EC VCN 200 EC C Unit voltage V 50 60 Hz 1 230 Power W 89 103 92 92 79 102 Current A 0 53 0 83 0 75 0 75 0 67 0 86 Air flow m3 h 313 480 550 585 535 755 RPM min 1 3460 3600 284...

Page 7: ...hase AC 220 230 V 50 60 Hz power mains For electric installations use insulated durable heat resistant wires with the minimum wire cross section 1 mm2 The actual conductor cross section selection must be based on its type the maximum permissible heating insulation length and installation method The external power input must be equipped with an automatic circuit breaker built into the stationary wi...

Page 8: ...cover and tighten the screws Wiring diagram of the fan with an asynchronous motor N L L X QF N PE Wiring diagram of the fan with an EC motor N 10V CTR GND L L X1 QF N PE For the operation of the EC motor it is necessary to install a speed controller not included in the delivery set or to short circuit the contacts 10V and CTR the fan will run at maximum speed ...

Page 9: ...ore the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature range 5 40 С and relative humidity up to 70 Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow th...

Page 10: ...ty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of...

Page 11: ...ian s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical codes and standards The unit operates normally as intended by the manufacturer Signature Seller Seller s Stamp Address Phone Number E mail Purchase Date This is to certify acceptance of the complete unit delivery wi...

Page 12: ...V06EN 04 ...

Reviews: