background image

5

INTRODUCTION

The user’s manual consisting of the technical details, operating instructions and technical specification applies to the installation and 

mounting of the heat recovery air handling unit VENTS VUT 2000-3000 PW EC, hereinafter referred to as «the unit».

PURPOSE

THE UNIT MAY NOT bE OPERATED bY CHILDREN OR PERSONS WITH REDUCED PHYSICAL, MENTAL 

OR SENSORY CAPACITIES, OR LACkING THE APPROPRIATE TRAINING.

THE UNIT MUST bE INSTALLED AND CONNECTED ONLY bY PROPERLY QUALIFIED PERSONNEL 

AFTER THE APPROPRIATE bRIEFING.

THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIzED ACCESS bY 

UNATTENDED CHILDREN.

DELIVERY SET

Name

Number

Unit

1 item

User's manual

1 item

Control panel

1 item

Packing box

1 item

Modification

L - left-handed modification

R - right-handed modification

Motor type

EC - electronically commutated motors

Heater type

W - water heater

Unit type

VUT - ventilation with heat recovery

Mounting method

P — suspended mounting

Air capacity [m3/h]

Control panel

__ — PU SENS 01 with a sensor display

А7 — PU JK 01 with an LCD display

VUT    ХХХ    PB   ЕС  -  Х  -  X

DESIGNATION kEY

The unit with a heat exchanger and a water heater is designed to save heat energy by means of heat recovery and is one of the energy 

saving components used in the buildings and premises. The unit is a component part and is not designed for independent operation. 

The unit is designed to provide permanent controlled air exchange by means of mechanical ventilation in houses, offices, hotels, cafés, 

meeting halls and other mechanically ventilated premises as well as utilization of extract air heat energy to warm up supply purified air.

The unit is designed for suspended mounting. 

The unit is rated for continuous operation.

Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, 

coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, pathogenic 

germs).

Summary of Contents for VUT 2000 PW EC

Page 1: ...VUT 2000 PW EC VUT 3000 PW EC USER S MANUAL Heat recovery air handling unit...

Page 2: ...data 6 Unit design and operating logic 8 Mounting and set up 9 Connection to power mains 13 Functional diagram 14 Technical maintenance 15 Fault handling 17 Storage and transportation rules 17 Manufa...

Page 3: ...e unit While transferring the unit control the User s manual must be turned over to the receiving operator Symbol legend UNIT MOUNTING SAFETY PRECAUTIONS WARNING DO NOT Disconnect the unit from power...

Page 4: ...s on it OFF ON Disconnect the unit from power mains prior to maintenance Do not let children operate the unit Do not damage the power cable while operating the unit Do not put foreign objects on the p...

Page 5: ...tion with heat recovery Mounting method P suspended mounting Air capacity m3 h Control panel __ PU SENS 01 with a sensor display 7 PU JK 01 with an LCD display VUT PB X DESIGNATION KEY The unit with a...

Page 6: ...B4 500 570 H 761 881 H1 367 427 H2 501 300 L 1400 1835 L1 1453 1888 Unit technical data Model VUT 2000 PW EC VUT 3000 PW EC Unit voltage V 50 60 Hz 1 230 3 400 Max fan power W 2 items 420 2 items 990...

Page 7: ...he black curve to the pressure drop axis 9 8 kPa How to use water heater diagrams System Parameters Air flow 3500 m3 h Outside air temperature 10 C Water temperature in out 90 70 C Air Speed Starting...

Page 8: ...e Condensate drain pipe Drain pan Extract filter Control unit Bypass Heat exchanger Bypass damper electric actuator SUPPLY AIR Unit operating logic top view based on VUT 2000 PW EC unit example The ba...

Page 9: ...000 mm 1300 mm min 20 mm B A min C Unit mounting The unit must be suspended to the ceiling on the threaded rod that is fixed inside a dowel Washer Nut Vibration damping rubber Nut and lock nut Example...

Page 10: ...ter mode the unit has following temperature limits The unit may not be started when the return heat medium temperature is below 40 C If the return heat medium temperature is 40 C and higher the unit w...

Page 11: ...s above 0 C If the expected ambient air temperatures are below 0 C the condensate drainage system must be equipped with heat insulation and pre heating facilities Condensate drain pipe Pipe Pipe Sewag...

Page 12: ...sory and is purchased separately Connect the contact socket of the humidity sensor to the contact socket located inside of the heat recovery unit After that fix the sensor using the clamp and the hold...

Page 13: ...mper actuator LF230 2 0 75 mm2 SM4 3 way valve actuator LR24 SR 3 0 75 mm2 PK1 Contact from fire alarm panel NO 2 0 75 mm2 P1 Control panel 4 0 75 mm2 TE1 Outdoor air temperature sensor 3 0 75 mm2 1 T...

Page 14: ...panel Q1 Water heater HV1 Duct humidity sensor HV2 Indoor humidity sensor RK1 Plate heat exchanger SM1 Supply air damper actuator SM2 Extract air damper actuator SM3 Bypass damper electric actuator SM...

Page 15: ...ntil they slide off the guides Install the filters in the reverse order 2 Heat exchanger cleaning once per year Some dust may accumulate on the heat exchanger block even in case of regular maintenance...

Page 16: ...Check the drain line operation by filling the drain pan under the unit with water clean the U trap and the drain line if necessary 5 Exhaust louvre shutters and intake diffusers cleaning as required W...

Page 17: ...r is soiled Clean or replace the extract filter The heat exchanger is frozen Check the heat exchanger for freezing Turn the unit off if required and restart it after the freezing danger is no longer i...

Page 18: ...ted on the unit packing and in the user s manual user s failure to ensure timely technical maintenance of the unit external damage to the casing excluding external modifications of the unit as require...

Page 19: ...ate is issued following test carried out on samples of the product referred to above Quality inspector s stamp This is to certify delivery of the complete unit with the user s manual Customer s signat...

Page 20: ...__________________________________________________________________________________ ___________________________________________________________________________________________________________ _________...