New fresh air inlet:
The conduit from the outside is connected here. 
To avoid condensation, it is recommended to use insulated conduits.
The new fresh air inlet should be fitted sufficiently far from any source of strong

The new fresh air inlet should be fitted sufficiently far from any source of strong 
contamination (Trees, combustion fumes, roads …).

Supply fresh air into the building:
The conduit blowing fresh reheated air into the building is connected here.
To avoid thermal losses it is recommended to use insulated tubes for moving the

To avoid thermal losses, it is recommended to use insulated tubes for moving the 
warmed air. 

Extracting air from the building:
The building’s air extraction conduit is connected here. 
To avoid thermal losses and optimise the performance of the installation, it is 

d d t

i

l t d t b

f

i

th

i

recommended to use insulated tubes for moving the warm air. 

Discharge extracted air to outside:
The conduit for discharging the extracted air from the building to the outside is 
connected here.
This conduit must be hermetic and thermally insulated to avoid condensation

This conduit must be hermetic and thermally insulated to avoid condensation 
both on the inside and outside.  

By-pass:

On having avoided the heat exchanger, the system of the by-pass 100 % of the
IDEO 275 Ecowatt allows the introduction of the fresh air in the night without

IDEO 275 Ecowatt allows the introduction of the fresh air in the night without
being warmed by the warm air accumulated in the house during the day. This
system works automatically or can be forced manually (See chapter 2-6-b).

Without  By-pass 

functioning

With By-pass

functioning

Summary of Contents for IDEO - 275 Ecowatt

Page 1: ...CTB IDEO 275 Ecowatt Installation Manual...

Page 2: ...Before manipulating this device disconnect the electricity supply During normal operation never stop the ventilation system...

Page 3: ...homes Soler Palau will not be held liable for damage produced by Misuse Normal wear and tear of components Non observance of the instructions contained in this manual regarding safety use and start up...

Page 4: ...ed airflows are separated and filtered Only the energy from the extracted air is transferred to the new fresh air introduced Thanks to IDEO 275 Ecowatt s high efficiency heat exchanger performance can...

Page 5: ...avoid thermal losses and optimise the performance of the installation it is d d t i l t d t b f i th i recommended to use insulated tubes for moving the warm air Discharge extracted air to outside Th...

Page 6: ...2 3 Dimensions Central unit Weight 51 Kg Remote controls Programmable module Kitchen boost...

Page 7: ...Wall bracket 2 4 Placement On a vertical wall On the floor It is recommended to locate IDEO in heated house space Otherwise it will be necessary to insulate the condensate drain pipework...

Page 8: ...fic kit option Support It is recommended to locate IDEO in heated house space Otherwise it will be necessary to insulate the condensate drain pipework necessary to insulate the condensate drain pipewo...

Page 9: ...Y Kitchen Outlet roof caps CT 150 Toilets BDOP 125 BDOP 80 Toilets Air intake plenum PAP Air intake D150 Li i itti Or PAF 150 Circular Air intake wall hoods Living sitting room Bedrooms Or Or PAST Air...

Page 10: ...TYPE DISTRIBUTION Outlet roof caps CT 150 Living sitting room BDOP 125 Kitchen BDOP 125 BDOP D80 RD80 Bedrooms Toilets BAR Toilets PAP Air intake D150mm BDOP D80 RD80 Or PAF 150 Circular Air intake D...

Page 11: ...aracteristics of each installation If any component is missing or badly fitted normal operation may be impaired H05VV F 5G1 type cable Length 1 2 m Connection box Electrical panel Power supply Single...

Page 12: ...type battery The programming module is located on the front of the machine This remote control can also be located on a wall The programming module is located on the front of the machine This remote c...

Page 13: ...or large flow 6 By pass 7 Defrost mode 7 Defrost mode 8 Absence mode 9 Transmission reception level 10 Battery level 11 Default mode 12 Change filter 12 Change filter 13 Instant energy saving 14 Energ...

Page 14: ...alidate with key 18 Validate with key 18 The pictogram with two fans will flash Validate with key 18 Adjust the maximum desired flow using keys 19 and 20 in 5 m3 h steps according to the configuration...

Page 15: ...ass Select with key 18 Select ON using keys 19 or 20 Validate with key 18 You can disable the forced by pass mode at any time To do this Navigate with keys 19 or 20 to pictogram 6 showing the By pass...

Page 16: ...played 11 This icon is displayed when one of the components is out of service motor probe This icon is displayed when one of the components is out of service motor probe sensor Or if the IDEO detects...

Reviews: