24407
ET25/30/36KX
C300
DATE
SECTION
SUPERSEDES
TITLE
Time of Truck Service
Service Interval
Note
Grease fitting With Pressure Grease Gun
Fill Oil Reservoir to Oil Level with Boom Down
A
B
Location
Service Required
Time of Truck Service
Time of Truck Service
Bolts should be torqued to 60 ft-lbs
Rope should be free of kinks and fraying
Check Wire Rope and Hook
D
C
Check Torque of bolts
-
09-03-19
LUBRICATION & MAINTENANCE CHART
Use Dextron III ATF or ISO Grade AW 46 for Ambient Temperatures
Use ISO Grade 68 or
Equivalent for Ambient Temperatures Between
Time of Truck Service
and as requried by
changes in the
ambient temperature
range
MANUFACTURING, INC.
CINCINNATI, OHIO
B
USE ELECTRICALLY CONDUCTIVE GREASE
Failure to use electrically conductive grease may
result in intermittent operation of the crane.
Example: Fuch's Renolit Aluminum Complex Grease
P/N 155250-2 (or equivalent).
A
A
D
A
C
Summary of Contents for ET30KX
Page 2: ......
Page 4: ......
Page 5: ...TFDUJPO 100 DESCRIPTION SPECIFICATIONS 7607100B ...
Page 10: ......
Page 12: ...TFDUJPO 150 SAFETY 8604150 ...
Page 21: ...TFDUJPO 200 JOTUBMMBUJPO 7607200B ...
Page 27: ...TFDUJPO 300 NBJOUFOBODF TFSWJDF 7607300B ...
Page 33: ...TFDUJPO 400 QBSUT 7607400B ...
Page 62: ......
Page 64: ......