ET SERIES CRANES
C300
12-26-13G
10-05-09F
MINIMUM VOLTAGE TEST
19963
®
MANUFACTURING, INC.
CINCINNATI, OHIO
ONE OF THE MOST COMMON ELECTRICAL PROBLEMS ENCOUNTERED ON
12 VOLT ELECTRICAL CRANES IS INSUFFICIENT VOLTAGE AT THE MOTOR
WHEN DRAWING THE LARGE CURRENT THAT EXISTS AT FULL LOAD
EXTEND BOOM CYLINDER
AGAINST "UP" STOP
(RELIEF VALVE WILL OPEN)
VOLTAGE AT MOTOR TERMINAL
WHEN OPERATING AGAINST RELIEF
VALVE SHOULD BE A MINMUM OF
9 VOLTS
BOOM ELEVATING
ELECTRIC HYDRAULIC
POWER UNIT
MINIMUM VOLTAGE TEST