After every spraying operation, the backpack pump must be cleaned in order to avoid nozzle corrosion and clogging due to
the products used. Moreover, cleaning avoids the stagnation of residues which could alter the product features during the
following use.
How to clean the backpack pump:
Empty any residual liquid out of the tank; the discharge cap on the side of the tank
can be used for this operation. Shake the backpack pump after filling it for 1/3 with water and pour its content. Repeat the
operation if necessary. Fill the pump again with clean water for at least 1/3 of the tank and operate it by spraying a large
volume of water out of the nozzle to ensure proper washing of all channels.
Improper cleaning leaving any residue could block the pump or clog the nozzles.
The outer part of the pump can be cleaned by using water and sponge.
Keep the backpack pump out of the reach of children and in a covered and dry place.
Keep the pump in vertical position and do not expose to direct sunlight.
V. CLEANING AND MAINTENANCE
VI. TROUBLESHOOTING
15
EN
Original instructions
We
Rama Motori S.p.A.
declare under our sole responsability that the
Battery-powered Knapsack Sprayer Futura 8l. - 5994 (5108)
and
Battery-powered Knapsack Sprayer Futura 12l. - 5998 (5112)
to which this declaration relates, correspond to the relevant basic
safety and health requirements of
2006/42/CE (Machinery Directive)
.
For the relevant implementation of the safety and health requirements
mentioned in the Directive, the following standard and/or technical
specification(s) have been respected:
ENISO 12100:2010
EN 62841-1:2015/AC:2015
EN 50580:2012/A1:2013
Notified body:
UDEM International Certification Mutlukent
Mahallesi 2073 Sokak
(Eski 93 Sokak)
No: 10 Cankaya - Ankara - TURKEY
The year of manufacture is printed on the label
put on the bottom of the sprayer.
Rama Motori S.p.A.
via Agnoletti 8 - 42124 Reggio Emilia RE
ITALY
Maintenance of Technical documentation:
Rama Motori S.p.A. - VERDEMAX Division
via Provinciale per Poviglio, 109
42022 Boretto RE - ITALY
phone no. +39 0522 481111
e-mail: verdemax@rama.it
DECLARATION OF CONFORMITY
The led light does not turn on when
operating the switch
Problem
Cause
Solution
- Low battery
- The power switch has been damaged
- The power cables are cut off
- Charge the battery
- Replace the switch
- Disassemble the pump to reconnect the cables
Inefficient spray
- The filter inside the tank is clogged
- The nozzle holes are clogged or damaged
- The disc inside the jet is assembled the wrong
way
- The tube joints are loosened
- The pump is damaged
- Clean the filter and remove any impurities
- Clean or replace the nozzle
- Install the nozzle correctly
- Tighten the joints
- Repair or replace the pump