7.0 Repairs and Replacements
7.6
Element Replacement
Disconnect the product from the electrical supply.
Remove the complete front panel. Remove the thermocouple cover and the square
plate from the back panel.
The elements are expensive and fragile and can be damaged by contamination: handle
them with care and keep them clean.
Replacements only: make a note of the actual braid and cable connections to the
elements. Disconnect the clips with the special tool provided (or with finger pressure,
depending on the type of clips supplied), lift off the braids and carefully withdraw each
element. See fig. 5.
Carefully insert the new elements into the product.
Attach the connection braids according to the note made above or to the appropriate
diagram, fig. 6. Use the special tool (or finger pressure) to fit the clips. Take care that
adjacent clips do not touch each other.
Replace the product end panels and connect the product to the electrical supply.
Fig.5. - Use of Clip Tool
Fig.6. Element Connections
7.7
Fuse Replacement
Fuses are marked on the wiring diagram with type codes, e.g. F1, F2. For more
information on fuses refer to section 10.0.
Depending on model and voltage, the different fuse types may or may not be fitted.
If any fuse has failed, it is advisable for an electrician to check the internal circuits.
Replace any failed fuses with the correct type. For safety reasons do not fit larger
capacity fuses without first consulting Carbolite Gero.
The fuses are located at the cable entry point. Remove the back panel or control box
back panel to gain access to the fuses.
26