Battery life 

Batteries can wear quickly if they are not used correctly. Fast wear falls outside the guarantee. 
 
 

Tips for a long battery life: 

1. 

It is recommended never to drive until the battery is completely flat. Further charging a nearly 
full battery is also advised against. 

2. 

Immediate charging of an empty battery considerably lengthens the working life. Discharging 
more than 20% affects the working life. 

3. 

Never interrupt charging and allow the battery to charge fully. 

4. 

If the V-move 4XL is taken out of use (for a lengthy period), it is advisable to keep the battery 
charger connected. This automatically keeps the battery charged. Make sure that the charger is 
connected to mains voltage, else it will drain the batteries instead of charging them. 

5. 

If the batteries are overly stressed, this will greatly shorten the working life. It is then necessary 
to adapt the pulling load of the vehicle.

 Also make sure to use the proper voltage for charging. 

6. 

It is advisable to not fully discharge the batteries. If this happens too often, faster wear will be 
the result. Keep a close eye on the battery condition meter. Connect the battery charger in good 
time.  

7. 

The batteries must be charged with the correct charger and for a certain time. If the charging 
current is too low or the duration of charging is too short, the batteries will not be fully charged 
and the capacity of the batteries will be too low for your use, with faster wear as a consequence. 
If the charging current is too high or the duration of charging is too long, the battery will become 
overcharged. The plates in your battery will then become overheated and can be damaged. 

8. 

If the batteries are only e.g. 60% empty and connected to the charger again, the batteries will 
not  have  time  to  rest.  The  temperature  of  the  batteries  will  rise  with  faster  wear  as  a 
consequence. The battery voltage will also be higher than the actual energy state so a discharge 
limiter will no longer work properly. 

9. 

The temperature of the battery may not become too high. This makes the acid more aggressive. 
Working with and charging in a cool space lengthens the working life.  

10. 

If the batteries are used on more than 3 days a week, they will wear more quickly.  

11. 

A  battery  gradually  empties  by  self-discharging.  If  a  battery  remains  in  a  discharged  state, 
sulphation will occur, resulting in irreparable damage. We therefore recommend recharging a 
stored V-move 4XL at least every 3 months. 

 
When  replacing  the  battery,  the  old  battery  must  be  disposed  of  according  to  the  locally  applicable 
regulations.

  

 

To avoid overheating of the battery charger is has to be mounted vertically to a wall. Warm air 
needs to be able to go up for proper heat dissipation. Air outlets must not be blocked. 

Summary of Contents for V-move 4XL

Page 1: ...erhagen Leiden B V Hoge Rijndijk 267 2314 AG Leiden T 31 0 71 581 30 30 F 31 0 71 541 61 89 info verhagenleiden nl www verhagenleiden nl USER MANUAL Original document V move 4XL Version 1 1 April 2019...

Page 2: ...in danger to the driver and or his her environment This product is supplied under the general delivery and payment conditions issued by the Metaalunie and designated as METAALUNIE CONDITIONS or as SM...

Page 3: ...ding on and off 8 4 2 Moving dragging the V move 4XL 8 5 Bringing into use 9 5 1 Inadvertent use 9 5 2 Checks before bringing into use 9 5 3 Top up battery water 10 6 Operation 11 6 1 Coupling the pro...

Page 4: ...r purposes than those for which Verhagen Leiden BV has made the appliance This can result in damage and danger to the driver and his her environment The control unit for the V move 4XL is supplied wit...

Page 5: ...whether your V move 4XL has been licensed for driving in your work environment or have this checked for example for environments with a fire hazard or danger of explosion When driving sparks can be ca...

Page 6: ...gradients The V move 4XL is only intended for driving on flat dry paved and sufficiently load bearing surfaces Always wear safety shoes during all work with the V move 4XL 2 3 Definitions Driver Perso...

Page 7: ...Leiden B V Hoge Rijndijk 267 2314 AG Leiden T 31 0 71 581 30 30 F 31 0 71 541 61 89 6 info verhagenleiden nl www verhagenleiden nl 3 Description of parts 3 1 Machine summary V move 4XL A 5 6 7 4 3 8...

Page 8: ...g cover plate 5 Motor controller indicator 6 Emergency stop button 7 Rating plate 8 Remote manual operation switch 9 Programming connection 10 Counterweight 11 Tiller head handle 12 Driving switch for...

Page 9: ...es to prevent further damage 4 1 Loading on and off Prevent injury and damage by wrongly positioning the lifting forks of the fork lift truck If the V move 4XL has to be moved with a forklift truck th...

Page 10: ...lace 5 2 Checks before bringing into use Besides good maintenance the driver of the V move 4XL must check the following points after each work period Check whether there is damage to the exterior of t...

Page 11: ...off the V move 4XL 3 Open the battery housing cover plate 4 Disconnect the battery s electric connections 5 Connect a water reservoir to the filling tube 6 Allow water to run into the battery a Use on...

Page 12: ...1 Unlock the emergency stop button if this has been pressed 2 Switch the ignition on 3 To switch to remote control please read paragraph 6 5 and return to step 5 in this paragraph 4 Move the tiller ar...

Page 13: ...emote control Both cannot be used at the same time and therefore it is nescessary to switch between the two Procedure 1 Make sure the steering arm is raised and leave it in the upright position 2 Wait...

Page 14: ...ive at 50 of its normal speed The V move 4XL must then be charged When the batteries have discharged to 20 of their capacity the V move 4XL will stop Procedure 1 The connection plug for the battery ch...

Page 15: ...ashes in the eyes for at least 5 minutes with clean water and immediately see a doctor 7 1 Preventive maintenance The V move 4XL is lubricated set and has been test run at your supplier Normal usage i...

Page 16: ...ediately drives at high speed Cause Solution Speed regulator defective Have replaced Relay defective Have replaced In case of a fault with the cause not immediately clear we advise you to contact Verh...

Page 17: ...h the correct charger and for a certain time If the charging current is too low or the duration of charging is too short the batteries will not be fully charged and the capacity of the batteries will...

Page 18: ...Machinery Directive 2006 42 EC meets the requirements of harmonised European Standards Harmonised European Standard Description Harmonised European Standard Description NEN EN ISO 12100_2010 Safety o...

Reviews: