26
CHAP. 3.8
TROUBLESHOOTING
In case of malfunctions of the air conditioner, check the items in the table below
If after making the suggested checks the problem is not solved, contact VERINE TECHNICAL SERVICE
Telephone
01787 472551
Fax
01787 272316
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
The Air conditioner does not switch on
Make sure power is being supplied.
Make sure main circuit breaker is closed
and the fuse is not burned out .
Close Circuit breaker.
Replace fuse.
If instead of circuit breaker you have a
cutoff switch, make sure it has not been
tripped.
Reset if necessary.
The batteries in the remote are dead. If
the batteries are dead you will notice the
absence of indications on the display and
the air conditioner will not beep when
sending a command.
Replace the batteries.
The device no longer cools satisfactorily
The temperature set on the remote
control is too high or too low (for
models with heat pump).
Check and, if necessary, correct the
temperature settings on the remote
control.
The air filter is clogged before the alarm
indictor lights up .
Check and clean if necessary.
Something is obstructing the airflow to
the inside or to the outside.
Remove anything that could obstruct the
airflow.
There has been an increase in the heating
or cooling load (e.g. door left open).
Make sure doors and windows are
closed. If a heat source has been
installed in the room that raises the
temperature excessively and for which
the air conditioner is unable to
compensate, the only solution is to
install another air conditioner.
The air conditioner stops and the second
and third LED from the left on the
control panel ,(orange, green and red
lights) start flashing
If there should be a malfunction in the
condensation water drain system, the air
conditioner stops working and signals,
wit h flashing orange, green and red light
Call Technical Service. To enable you to
use the unit temporarily until the service
personnel arrive, you can drain the water
out by following these instructions:
-
Grasp the rubber cap on the bottom
centre of the air conditioner behind
the edge of the frame facing the wall
between your thumb and forefinger.
-
Pull the rubber tube closed by the
cap out by a few centimetres.
-
Remove the cap after placing a
bucket or other container underneath
it (at least five litre capacity) to
collect the water.
-
After eliminating the malfunction the
service personnel will take care of
closing the evacuation tube.
IMPORTANT: if you unable to classify the problem as one of those described above, you should
immediately get in touch with o ur Service Department without atte mpting to make repairs yourself.