Preliminary Notes Before Installation
This appliance is a high efficiency, flueless, flame effect gas fire. It provides radiant and
convected warmth both efficiently and safely utilizing the latest type catalytic converter
burner technology.
The appliance incorporates a combustion monitoring system (Oxygen Depletion System). It
must not be adjusted or put out of operation. If replaced then manufacturers original parts
must be used.
The appliance is designed to fit various types of situations as listed in the Installation
Requirements.
This appliance must be installed in accordance with the rules in force and only used in a
sufficiently ventilated space. A minimum of
100cm
2
(15.5in
2
)
purpose provided ventilation
is required for this appliance. An openable window or louvre is also required. This
appliance is factory set for operation on the gas type, and at the pressure stated on the
appliance data plate.
The room size should be a minimum of
30m
3
(1059ft
3
)
to allow adequate circulation of air
and ensure the correct operation of the fire. This volume may include adjacent spaces but
these spaces must not be separated by a door. In order to convert from cubic feet (ft
3
) to
cubic meters (m
3
) divide the room volume (in ft
3
) by 35.3. This appliance is intended as a
secondary source of heat only and should not be used in a room without some form of
background heating present.
The appliance must not be installed in a bedroom, bathroom or any sleeping area. The
appliance does not require a flue system of any type as the catalytic converter cleans the
flue products to provide a complete combustion system, which is intrinsically safe.
The appliance must be installed by a competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998 or rules in force. It is strongly recommended that a
CORGI registered engineer is used for this purpose, as they are the only persons approved
by the HSE under the above regulations.
On initial lightup of a new appliance, the ‘newness’ will burn off within the first few hours
of operation. During this period some smoke may be emitted from outlet grille, this should
be no cause for concern. Accordingly, the room should be well ventilated with all windows
and doors open during this period.
Read all these instructions before commencing installation. All instructions must be
handed to user for safekeeping.
Important Notes
This appliance is a catalytic flueless flame effect gas fire, providing radiant and convected
warmth. It is designed to operate on Natural Gas following factory set adjustments, (see
Data Plate on appliance for gas type and pressure).
It is the LAW that all gas appliances and fittings are installed by a competent person (such
as a CORGI registered fitter) and in accordance with the Gas Safety (Installation and Use)
Regulations 1998, the relevant British Standards for Installation, Codes of Practice and the
Manufacturers' Instructions. The installation shall also be carried out in accordance with
the following regulations:
The Building Regulations issued by the Department of the Environment, the Building
Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development
Department.
Relevant British standards insofar as the relevant areas are not covered by these
instructions.
Note: For Republic of Ireland, reference should be made to the relevant standards