3
These instructions primarily cover the installation of the rear-venting version of the Fanfare
fan unit, but pages 17 to 21 of these instructions deal with the side venting
application and must be referred to when fitting the side venting model.
Before commencing the installation ensure that all the components listed below are included
in the packaging.
Fire Box
Fan Box
1 - Firebox and burner
1 - Fan Box
1 - Set of ceramic components.
1 - Fibre Rope Sealing Gasket
a)
Upper rear ceramic
1 - Fan Box Flue Spigot
b)
Upper front ceramic
3 - No8 x
3
/
8
Screws
c)
Middle ceramic
1 - Brick Clamping Plate
1 - Fan Spacer*
Roll of sealing tape.
1 - Bag of 23 coals
1 - Magnetic Trim
1 - Flue Duct 100mm x 50mm x 500mm
Installation and Servicing Instructions. Users Instructions. Guarantee Card.
•
= The fan spacer is supplied if ordered separately. It will be required only if the
rebate on the surround or the fake chimneybreast is less than 51mm (2”). If fitted to
a standard 292mm (11
1
/
2
“) cavity wall.
APPLIANCE DATA
NPFC/P00T/MN
NPFC/P00T/MP
Gas Type
Natural Gas
Propane
Jet Size (mm)
2.05
1.31
Maximum Input (Gross)
6.7kW
6.0kW (430g/hr)
Inlet Pressure (mbars)
20
37
Gas Connection
8mm Compression
Mains Supply Voltage
220 – 240V
Mains Supply Frequency
50Hz
Fuse Rating
3Amps
Dimensions
H: 585mm, W: 490mm, D: 130mm