Technical Data RP 406K (–IC) 

CCD Sensor 

1/3“ Sony Exview Interline CCD 

Max. pixels (h x v) 

768 x 576 

Horizontal resolution 

470 TV lines 

Sensitivity 

0.015 lux on sensor / 0.3 lux with F2.0 

TV standard 

PAL, 625 lines 

Enhancer 

Yes 

Gamma correction 

0,45 

Electronic shutter 

Automatic, 1/50 -1/100,000 sec. 

Signal-to-noise ratio 

50 dB (AGC off) 

AGC 

30 dB 

Synchronization 

Internal 

Backlight 

Automatic 

Spectral response 

380 -660 nm 

Smear effect 

0,005%  

Video output signal 

FBAS 1Vss / 75 Ohm, BNC 

Operating voltage 

12V/DC (DC 8,0 -15.0 V) 

Performance 

Max. 2 W 

Operating temperature 

-10° to +50°C 

Extended temperature area according to 
EN501155-T1 

-25° to +70°C 

Humidity 

90 % (not condensed) 

Protective system according to association
German electrotechnicians (VDE) 

IP41, class III 

MTBF 

80,000 hours 

Housing shape 

Mini dome camera (black) 

Connections 

Connecting cables with open cable ends (12VDC) / BNC 
plugs (video) 

Weight 

Approx. 300 g 

Installation 

RP 406K: Wall/ceiling mounting

 

RP 406K-IC: Wall/ceiling installation 

Lens 

RP 406K: 2.9mm; 3.6mm; 4.3mm, 6mm; 8mm

 

RP 406K-IC: 4.3mm 

Dimensions (diameter / height) 

RP 406K: 79 mm / 56.5 mm

 

RP 406K – IC: 79 mm / 62 mm

 

Extended product standards 

EN 50155 
"e" mark 
EN 50121-3-2 
DIN 5510 

 
 

 

10 

Summary of Contents for RP 400 Series

Page 1: ...Mounting and Operating Instructions of RP406K and RP406K IC for mobile video surveillance 12 2005 ...

Page 2: ...evice This way you can completely enjoy all the benefits this product provides In presenting this document Verint Systems does not make any guarantee regarding the correctness or completeness of its contents and reserves the right to alter this document at any time without notice This document may not be duplicated photocopied reproduced translated transferred to an electronic medium or converted ...

Page 3: ... delivery 5 Accessories additional devices 5 Warranty 5 Installation 6 System overview 6 Detailed view 6 Monunting 7 Connecting diagram 8 Appendix 10 Technical Specifications 10 Claening and maintenance Servicing information 11 Error search 11 Technical support 12 Notice 13 Version Date Ver 1 0 08 12 2005 3 ...

Page 4: ...volous lawsuits Safety information Read these instructions carefully before operating the device This will help prevent possible damages from improper use The device should only be installed by qualified professionals according to existing VDE Association for Electrical Electronic Information Technologies regulations Operate the cameras exclusively using the normal service voltage indicated Observ...

Page 5: ...orking days following delivery of the product Hidden defects must be reported immediately when they are discovered The warranty does not include damages to the products caused by accidents unsuitable or improper usage non authorized or incorrect mounting or startup incorrect or improper handling damages during transport or improper maintenance The warranty does not include costs you incur from ins...

Page 6: ...K IC dome camera needs a stabilized power supply of 12 V DC and has a power consumption of max 2 0 W Cable connections It is possible to lay separate cables for all connections Video coaxial cable 75 Ω F BAS 1 Vss 75 Ω Power supply Operating Voltage 12 V DC GND Detailed view All specifications in mm 6 ...

Page 7: ...The best image quality will be achieved if both camera and lighting point to the area you want to record Reduce the picture section to the essential area and install the camera as close to the object as possible Avoid head lights as back light in the video picture also caused by reflections e g on window panes Mounting the camera on a wall or ceiling Always proceed in the following order to mount ...

Page 8: ...t and ensure the housing seal fits correctly Protect the housing from unauthorized opening by using the fixing screw with the hexagonal socket screw key included in the shipment RP 406K IC Make a suitable fitting mounting aperture diameter 60mm fitting depth approx 35mm for the fitted camera and fasten the camera with the mounting material included in the shipment The camera can be installed on a ...

Page 9: ... and make sure the connector fits correctly and cleanly and has the correct polarity Operate the camera exclusively using the normal service voltage indicated The mating component of the system voltage plug Wago male is included in the scope of delivery Initial operation Check to see that the camera provides an acceptable video signal and that the picture section was chosen correctly The camera sw...

Page 10: ...ing voltage 12V DC DC 8 0 15 0 V Performance Max 2 W Operating temperature 10 to 50 C Extended temperature area according to EN501155 T1 25 to 70 C Humidity 90 not condensed Protective system according to association German electrotechnicians VDE IP41 class III MTBF 80 000 hours Housing shape Mini dome camera black Connections Connecting cables with open cable ends 12VDC BNC plugs video Weight App...

Page 11: ... The instructions should be included if giving the device to a third party Error search Error description Cause Camera station does not send a video signal Check the connection of the service voltage 12 V DC Check the connection of the video cable at the camera Check to see that your power supply is functioning 12 V DC Check the connections to the camera video voltage The video picture is too dark...

Page 12: ...Appendix Technical support Should difficulties arise while installing or operating the device we offer you technical support at 49 0 4321 269 81 36 or at mobilesupport verint com 12 ...

Page 13: ...Notes 13 ...

Page 14: ...Notes 14 ...

Page 15: ...Notes 15 ...

Page 16: ...Configuration Verint Video Solutions GmbH Norderhofenden 12 13 D 24937 Flensburg Tel 49 0 461 14 15 90 Fax 49 0 461 14 15 9 10 Email mobilesupport verint com Service hotline 49 0 4321 269 81 36 16 ...

Reviews: