HOW YOUR VERIPURE® SYSTEM WORKS  

 

YOUR PATENTED VERIPURE® SYSTEM HAS BEEN DESIGNED TO USE TWO STAGES OF PRIMARY FILTRATION 
AND LOW LEVEL OZONE TECHNOLOGY®. OPERATIONAL MAINTENANCE AND REPLACEMENT REQUIREMENTS 
ARE    ESSENTIAL FOR THE VERIPURE® SYSTEM TO PERFORM TO SPECIFIATIONS. CONTACT YOUR LOCAL 
DEALER OR  DISTRIBUTOR FOR REPLACEMENT FILTERS AND PARTS, OR CONTACT VERIPURE FOR THE DEALER 
NEAREST YOU. THE VERIPURE® SYSTEM IS RECCOMENDED TO BE CONNECTED TO MUNICIPAL WATER 
SOURCES. 

FOOD & SURFACES 

GENERAL RECOMENDATIONS FOR USING OZONATED WATER ARE AS FOLLOWS- 

 

PLACE ITEM OR ITEMS TO BE WASHED UNDER A STEADY STREAM OF VERIPURE® WATER AND RINSE. 

 

FOOD PREPARATION: IT IS RECOMMENDED ITEMS BE RINSED FOR 3 MINUTES WITH VERIPURE® WATER. 

 

FOOD ITEMS: PLACE IN A BOWL, COLANDER OR STRAINER. RINSE WITH VERIPURE® WATER. 

STORING WATER  

 

SELECT A CONTAINER THAT IS FOOD GRADE QUALITY, SUCH AS GLASS OR STAINLESS STEEL. THOROUGHLY RINSE 
THE CONTAINER WITH VERIPURE® WATER AT LEAST TWICE. FILL THE CONTAINER TO WITHIN ONE TO TWO INCHES 
FROM THE TOP AND REPLACE CAP. 

 

STORE WATER IN REFRIGERATOR AND MAKE CERTAIN THE CAP IS REPLACED AFTER EVERY USE. 

 

WHEN WATER IS FRESHLY OZONATED YOU MAY INITIALLY BE ABLE TO DETECT A SLIGHT HINT OF OZONE. PEOPLE 
VARY IN THEIR SENSITIVITY TO OZONE. ANY HINT OF THE OZONE TASTE WILL DISAPPEAR WITHIN A SHORT PERIOD 
OF TIME. YOUR SYSTEM PRODUCES MINIMAL WASTE WHILE PRESERVING MINERALS IN YOUR WATER. 

 

IMPORTANT NOTE:

  

VERIPURE® PERFORMANCE IS BASED UPON INPUT WATER WHICH MEETS MINIMUM 

EPA NATIONAL PRIMARY AND SECONDARY DRINKING WATER STANDARDS.                                                       
SEE 

WWW.EPA.GOV/DWSTANDARDSREGULATIONS 

Summary of Contents for VERIPUREVP5000

Page 1: ...1 REVISED 4 13 2020 OWNERS MANUAL VERIPUREVP5000...

Page 2: ...m THANK YOU FOR CHOOSING VERIPURE PLEASE TAKE A FEW MOMENTS TO FILL IN THE INFORMATION BELOW SAVE THIS MANUAL AS A CONVENIENT INFORMATION SOURCE FOR YOUR VERIPURE SYSTEM Date of Purchase Purchased Fro...

Page 3: ...ystems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Stage One Filtration Process The VeriPure Maintenance Kit Consists of a two filter configuration...

Page 4: ...THE WATER SUPPLY AT THE SINK OR WATER SOURCE AND UN PLUG POWER JACK FROM THE VERIPURE SYSTEM BEFORE PERFORMING ANY MAINTENANCE ACCESSORIES DO NOT USE ANY ACCESSORIES INCLUDING FILTER CARTRIDGES THAT A...

Page 5: ...OR 3 MINUTES WITH VERIPURE WATER FOOD ITEMS PLACE IN A BOWL COLANDER OR STRAINER RINSE WITH VERIPURE WATER STORING WATER SELECT A CONTAINER THAT IS FOOD GRADE QUALITY SUCH AS GLASS OR STAINLESS STEEL...

Page 6: ...6 A LOOK AT YOUR VERIPURE SYSTEM UNIT DIMENSIONS 11 5 L X 7 W X 5 5 H 9 0LBS 4 05KG IT IS IMPORTANT TO BE FAMILIAR WITH CERTAIN COMPONENTS OF YOUR VERIPURE SYSTEM FOR MAINTENANCE PURPOSES DIAGRAM 1...

Page 7: ...FORMANCE LIMIT YOUR VERIPURE SYSTEM TO 70 PSI OF WATER PRESSURE VERIPURE RECOMMENDS A MINIMUM WATER PRESSURE OF 50 PSI LOW WATER PRESSURE WILL CAUSE YOUR VERIPURE SYSTEM TO PRODUCE A LOWER QUANTITY OF...

Page 8: ...LISTED BELOW ARE INCLUDED QTY 1 AC ADAPTER POWER SUPPLY WITH OUTLET PLUG QTY 1 FAUCET ASSEMBLY QTY 1 FAUCET MANUFACTURES INSTRUCTION SHEET QTY 1 3 8 TUBING 4 IN LENGTH OUTLET HOSE TO FAUCET QTY 1 1 4...

Page 9: ...LY VALVE STEP6 THREAD THE COLD WATER FEED LINE INTO THE MALE THREADED END OF THE ANGLE STOP TEE STEP 7 LOCATE THE BEST AREA FOR HANGING THE VERIPURE SYSTEM MAKE CERTAIN THE INLET ASSEMBLY AND OUTLET T...

Page 10: ...WITH THE COLLET HELD IN THIS POSITION THE TUBBING CAN BE REMOVED THE FITTING CAN THEN BE RE USED STEP 11 CONNECT THE 1 4 WHITE TUBBING TO THE ANGLE STOP TEE MAKE SURE WHITE TUBBING IS FULLY SEATED IN...

Page 11: ...COLOR UNTIL THE CARBON FILTER IS THOROUGHLY RINSED THE GRAY COLOR WILL DISAPPEAR QUICKLY FLUSHING INSTRUCTIONS TURN ON THE WATER SUPPLY AND FLUSH NEW CARTIDGES FOR 5 MINUTES RUNNING WATER THROUGH THE...

Page 12: ...is malfunctioning LED READOUT INSTALLED VERIPURE There are two maintenance requirements for your VeriPure System 1 Change the filter cartridge assembly when indicated by the LED readout on your VeriP...

Page 13: ...l no water comes out Then close the faucet 4 Disconnect the 1 4 input line from the filter and 3 8 output line on your VeriPure System using spanner tool provided in maintenance kit Refer to Diagram 1...

Page 14: ...ed line up mounting guide holes to guide bolts on mounting plate Allow unit to seat into place checking stability before releasing unit from your grip Tighten screws on mounting plate 2 Reconnect wate...

Page 15: ...ick 4 Slowly remove the Dielectric tube from the VeriPure housing by sliding the Dielectric out IN A STRAIGHT LINE until the Dielectric tube is completely separated from the VeriPure housing 5 The old...

Page 16: ...E OF WATER LEAKAGE If a water leak is detected REPEAT Returning Unit to use Steps 2 4 TROUBLE SHOOTING GUIDE At VeriPure Inc we expect your VeriPure System to function properly for years as long as yo...

Page 17: ...SURE WILL NOT ALLOW YOUR SYSTEM OZONATION COMPONENTS TO TURN ON REGAIN INCOMING WATER PRESSURE TO MINIMUM OF 50 PSI CONTACT YOUR PLUMBER OR MUNICIPALITY DROP IN OR NO WATER FLOW PLUGGED FILTER CHANGE...

Page 18: ...OES THE OZONE AFFECT THE TASTE OF THE WATER Initially there is a slight aroma of ozone This dissipates after a short period of time approximately 20 seconds IS THE OZONE GAS RELEASED INTO THE AIR BY V...

Page 19: ...aler in a timely manner following discovery of the claimed defect Any claim under this warranty must be made within 30 days following the expiration of the one year warranty VeriPure LLC reserves the...

Reviews: