Table 1-5
System Status LED states
Description
Criticality
State
Color
■
System is power off (AC and/or DC)
■
System is in EuP Lot6 Off Mode
■
System is in S5 Soft-Off State
■
System is in S4 Hibernate Sleep State
Not ready
Off - The
system is not
operating
No
color
Indicates that the system is running (in S0 State)
and its status is “Healthy”. The system is not
exhibiting any errors. AC power is present and
BMC has booted and manageability functionality
is up and running.
Healthy
Solid on
(SO)
Green
System degraded:
■
Redundant loss, such as power supply or fan.
Applies only if the associated platform
sub-system has redundancy capabilities.
■
Fan warning or failure when the number of
fully operational fans is more than minimum
number needed to cool the system.
■
Non-critical threshold crossed: Temperature
(including HSBP temp), voltage, input power
to power supply, output current for main
power rail from power supply and Processor
Thermal Control (Therm Ctrl) sensors.
■
Power supply predictive failure occurred while
redundant power supply configuration was
present.
■
Unable to use all of the installed memory (one
or more DIMMs failed/disabled but functional
memory remains available).
■
Battery failure.
■
BMC executing in uBoot. (Indicated by
Chassis ID blinking at 3Hz). System in
degraded state (no manageability). BMC
uBoot is running but has not transferred
control to the BMC Linux. Server will be in
this state 6-8 seconds after BMC reset while
it pulls the Linux image into flash.
Degraded
The system is
operating in a
degraded state
although still
functional.
or
The system is
operating in a
redundant state
but with an
impending failure
warning.
~1 Hz blink
Green
15
About the NetBackup 5240 Appliance
NetBackup 5240 Appliance control panel