Table A-2
Veritas 2U12 49TB Storage Shelf technical specifications
(continued)
Description
Technical specification
50/60Hz
AC Frequency range
>80% @ 100V, >80% @240V (>30% load)
Power conversion efficiency
63 dBA
Acoustic noise
-300 to 12,192 m (-1,000 to 40,000 ft)
Non-operational altitude
2g 11mSec half sine
Operational shock
25g 10mSec half sine
Non-operational shock
0.21g RMS 5-500Hz random
Operational vibration
1.04g RMS 2-200Hz random
Non-operational vibration
0.3g 2-200Hz sinusoidal
Relocation vibration
(Non-operational)
See
“Environmental specifications”
on page 59.
Environmental specifications
The following table lists the environmental specifications for the NetBackup 5240
Appliance and the Veritas 2U12 49TB Storage Shelf.
Table A-3
NetBackup 5240 Appliance and Veritas 2U12 49TB Storage Shelf
environmental specifications
NetBackup 5240 Appliance / Veritas 2U12 49TB
Storage Shelf
Specification
ASHRAE A2 (10°C to 35°C ) (50°F to 95°F)
Operating temperature
-25°C to 70°C (-13°F to 158°F)
The non-operating temperature is defined as the temperature
of the system when the system is turned off. It is also referred
to as the storage temperature.
Veritas recommends that you do not store the system in an
environment where the temperatures fall outside of the listed
temperature range.
Non-operating temperature
59
Technical specifications and compliance standards
Environmental specifications